Patient Warmer Portable ICU Surgery Warming System
In stock
Share this product
Patient Warmer Portable ICU Surgery Warming System
The Portable Patient Warming System is a professional forced-air patient warmer designed to support controlled body warming in hospitals, operation theatres, ICUs, emergency departments, recovery rooms and surgical care areas. It helps clinical teams manage patient temperature support by delivering warm air through a flexible air duct into a compatible warming blanket.
This patient warming system offers 13 temperature levels, 3 air volume settings, real-time temperature display, safety self-check, visual and auditory alarms, double-layer filtration and a filter maintenance timer. Its compact desktop design and weight under 6 kg make it practical for OT, ICU, recovery and procedure room use under trained healthcare supervision.
Key Features
- Portable forced-air patient warmer for ICU, OT and surgery care areas.
- 13 temperature levels including room temperature and 32°C to 43°C settings.
- Three air volume levels: high, middle and low for different warming needs.
- Clear display shows set temperature, current temperature, room temperature and working status.
- Current temperature display accuracy of 0.1°C supports close monitoring.
- Safety self-check with visual and auditory alarm support.
- High temperature, low temperature, over-temperature and sensor alarm functions.
- Blower fault and heater fault alarms support safer operation.
- Double-layer air filtration with primary filter and high-efficiency filter ≤0.2µm.
- Filter replacement reminder after running time exceeds 1000 hours.
Technical Specifications
| Product Type | Forced Air Patient Warming System |
|---|---|
| Equipment Use | Physical warming of the human body by controlling warming blanket temperature |
| Design | Desktop / Portable Design |
| Temperature Choice | 13 Levels Including Room Temperature; 32°C-43°C in 1°C Steps |
| Temperature Accuracy | ±0.9°C as per supplied details |
| Temperature Sensors | Three-Piece Temperature Sensors for System and Outlet Airflow Monitoring |
| Display Parameters | Set Temperature, Set Air Volume, Current Temperature, Room Temperature, Working Time and Working Status |
| Current Temperature Display Accuracy | 0.1°C |
| Air Volume | High ≥40 CFM, Middle ≥35 CFM, Low ≥30 CFM |
| Noise Level | ≤53 dB(A) at High Air Volume; <45 dB(A) at Low Air Volume |
| Safety Functions | Safety Self-Check, Visual Alarm, Auditory Alarm, High Temperature Alarm, Low Temperature Alarm, Over-Temperature Alarm and Temperature Sensor Alarm |
| Fault Alarms | Blower Fault Alarm and Heater Fault Alarm |
| Filter System | Double-Layer Air Filtration: Primary Filter and High-Efficiency Filter ≤0.2µm |
| Operation Mode | Button Operation |
| Warming Blanket Compatibility | Adult Blankets, Size 200 x 100 cm as per supplied details |
| Power | >1700 VA |
| Air Duct | Elastic, Flexible, Wear-Resistant, Good Sealing Properties; Length >1.8 Meters |
| Power Cord | Length >5 Meters |
| Waterproof Level | IPX3 |
| Product Size | 27 x 25 x 26 cm |
| Weight | <6 kg |
| Time to Reach Set Temperature | Stabilizes Within Selected Temperature Range Within 3 Minutes |
| Timer | Records Running Time and Working Time; Filter Replacement Prompt After >1000 Hours |
| Operating Environment | Ambient Temperature 5°C-30°C, Relative Humidity 30%-75%RH, Atmospheric Pressure 700-1060 hPa |
Benefits of Patient Warmer
This patient warmer supports controlled warming workflow in OT, ICU, recovery and emergency care environments. As a result, healthcare teams can manage warming temperature, airflow and safety monitoring from one compact forced-air system.
- Supports patient warming before, during or after selected clinical procedures.
- 13 temperature levels help match warming support to patient needs.
- Three air volume settings provide flexibility for different care situations.
- Display helps staff monitor temperature, air volume, working time and status.
- Safety alarms support faster awareness during abnormal temperature or device fault conditions.
- Double-layer filtration supports cleaner airflow during operation.
- Compact size and weight under 6 kg support easy movement and placement.
- Maintenance reminder helps plan filter replacement after extended use.
Who Should Buy This?
The Portable Patient Warming System is suitable for healthcare facilities that need a compact forced-air warming device for supervised patient care. Moreover, it is useful where adjustable temperature, controlled airflow, filtration and alarm protection are required.
- Operation theatres for surgical patient warming support.
- ICU departments for controlled warming workflow under supervision.
- Recovery rooms for post-procedure patient temperature support.
- Emergency departments for clinical warming support where required.
- Procedure rooms for selected patient warming applications.
- Surgical departments for OT and perioperative care workflow.
- Healthcare buyers looking for a portable patient warmer.
Common Applications
- ICU patient warming support
- Operation theatre warming workflow
- Surgical patient temperature support
- Recovery room warming care
- Emergency department warming support
- Procedure room patient warming
- Forced-air warming with compatible blankets
- Clinical temperature support under trained supervision
How to Use Safely
- Place the patient warmer on a stable surface near the care area.
- Connect the power cord to a suitable power supply.
- Inspect the air duct, filter status and display panel before use.
- Connect the air duct securely to the compatible warming blanket.
- Select the required temperature level and air volume as per clinical protocol.
- Monitor set temperature, current temperature, room temperature and working status.
- Respond immediately to visual or auditory alarms.
- After use, switch off the device, disconnect the duct carefully and follow cleaning guidance.
Why Choose This Portable Patient Warming System?
This portable patient warming system is designed for hospitals and clinical departments that need a compact forced-air warming solution with adjustable temperature, adjustable airflow, clear display, filtration and alarm protection. In addition, its fast temperature stabilization and maintenance prompt make it practical for routine OT, ICU and recovery room workflow.
- Compact forced-air patient warmer for hospital use.
- 13 temperature levels and 3 airflow settings support flexible operation.
- Double-layer filtration supports cleaner airflow.
- Alarm system supports safer warming workflow.
- Good choice for ICU, surgery, OT, recovery and emergency care areas.
FAQs
What is a patient warmer used for?
A patient warmer is used to support physical warming of the human body using controlled warm airflow through a compatible warming blanket.
What temperature settings are available?
This system offers 13 temperature levels, including room temperature and 32°C to 43°C in 1°C steps.
What air volume levels does it support?
It supports three air volume levels: high ≥40 CFM, middle ≥35 CFM and low ≥30 CFM.
What safety alarms are included?
The system includes visual and auditory alarms for high temperature, low temperature, over-temperature, sensor alarm, blower fault and heater fault conditions.
Does this patient warmer have filtration?
Yes, it has a double-layer air filtration system with a primary filter and high-efficiency filter ≤0.2µm.
Who should operate this patient warming system?
This patient warming system should be operated by trained healthcare professionals following the user manual, patient condition and facility protocol.

