Skip to content

India's Trusted Medical Equipment Supplier

Neonate Intubation Model for Oral & Nasal Airway Training

Save 20%
Regular price
Sale price Rs. 17,500 Regular price Rs. 22,000
Tax included.

In stock

1 Lakh+
Hospitals Served
22,000+
Delivery Pincodes
CE & ISO
Certified Device
EMI
Easy Financing
  • Free Shipping
  • Easy Return

Ask a question

The fields marked * are required.

Neonate Intubation Model for Oral and Nasal Airway Training

The Neonate Intubation Model for Oral and Nasal Airway Training is a professional neonatal airway simulation trainer designed to support controlled practice of newborn intubation and basic airway-management techniques. It provides medical students, nurses, paramedics, doctors and clinical instructors with a realistic training platform before supervised procedures are performed in clinical environments.

This neonate intubation training model is suitable for medical colleges, nursing institutes, teaching hospitals, neonatal intensive care units, paediatric departments, emergency medicine skill laboratories and healthcare simulation centres. Its true-to-life newborn proportions help learners understand the smaller airway dimensions and positioning considerations associated with neonatal airway management.

The model supports both oral and nasal intubation practice. Learners can use suitable neonatal training equipment to practise laryngoscope handling, airway visualisation, endotracheal tube insertion and basic head positioning. The flexible neck allows the head to be adjusted during demonstrations, while the stable training base helps keep the model secure throughout repeated practice sessions.

Its soft-touch construction is intended to provide a more realistic simulation experience than rigid demonstration-only models. The reusable design makes it suitable for structured classroom demonstrations, neonatal resuscitation workshops, supervised skills practice and competency-based training programmes.


neonate intubation model medansh

Key Features

  • Realistic Neonatal Anatomy: Represents the newborn head, mouth, nose, neck and upper airway in true-to-life proportions.
  • Oral Intubation Practice: Supports supervised laryngoscope handling, airway visualisation and oral endotracheal tube insertion.
  • Nasal Intubation Practice: Allows learners to practise nasal airway access and suitable neonatal tube placement techniques.
  • Flexible Neck Design: Helps instructors demonstrate appropriate head positioning for different neonatal airway-training scenarios.
  • Laryngoscope-Compatible Airway: Designed for repeated airway visualisation practice using suitable neonatal training equipment.
  • Endotracheal Tube Training: Supports practice of tube advancement, placement and removal under instructor supervision.
  • Soft-Touch Construction: Provides a more practical tactile experience during airway and intubation simulation.
  • Stable Training Base: Keeps the model secure during demonstrations, individual practice and structured skills assessment.

Technical Specifications

Specification Details
Product Name Neonate Intubation Model for Oral and Nasal Airway Training
Product Category Neonatal Airway and Intubation Training Simulator
Training Area Newborn Head, Neck and Upper Airway
Practice Methods Oral and Nasal Intubation
Supported Training Equipment Laryngoscope and Suitable Neonatal Endotracheal Tubes
Neck Design Flexible for Head Positioning
Material High-Quality Soft-Touch PVC or Silicone, as Supplied
Model Size True-to-Life Newborn Dimensions
Mounting Model on Stable Training Base
Usage Type Educational and Simulation Use
Primary Applications Neonatal Airway Management, Intubation Practice and Clinical Simulation Training
Accessories May vary depending on supplied configuration; confirm before purchase

Product Benefits

  • Supports Pre-Clinical Skill Development: Helps learners understand neonatal airway anatomy and procedural steps before supervised clinical practice.
  • Improves Instrument Handling: Repeated practice supports better control of the laryngoscope and endotracheal tube during simulation.
  • Supports Oral and Nasal Techniques: Allows institutions to teach two commonly studied neonatal intubation approaches using one trainer.
  • Helps Practise Head Positioning: The flexible neck enables instructors to demonstrate positioning considerations for newborn airway access.
  • Provides Controlled Simulation: Enables early-stage procedural training without performing the technique on a real newborn.
  • Useful for Instructor Feedback: Trainers can observe hand placement, equipment handling and procedural sequence during practice.
  • Suitable for Repeated Institutional Use: The reusable design supports regular skill-lab sessions, workshops and competency training.
  • Supports Team-Based Education: Can be used for individual practice, group demonstrations and neonatal resuscitation training scenarios.

Applications

  • Neonatal oral intubation practice
  • Neonatal nasal intubation practice
  • Laryngoscope handling training
  • Airway visualisation exercises
  • Endotracheal tube insertion practice
  • Newborn head-positioning demonstrations
  • Neonatal resuscitation workshops
  • Paediatric airway-management education
  • Simulation-based competency training
  • Emergency medicine skill-lab sessions

Suitable Healthcare and Training Settings

  • Medical colleges and teaching hospitals
  • Nursing and paramedical institutes
  • Neonatal intensive care training programmes
  • Paediatric and neonatology departments
  • Emergency medicine skill laboratories
  • Clinical simulation centres
  • Neonatal resuscitation workshops
  • Healthcare competency-training programmes

How to Use

  1. Place the model securely on a clean, flat and stable training surface.
  2. Inspect the mouth, nasal passages, neck and simulated airway before beginning the session.
  3. Select suitable neonatal training equipment according to the model instructions and institutional protocol.
  4. Position the head and flexible neck under the guidance of a qualified neonatal or airway instructor.
  5. Insert the laryngoscope carefully and practise airway visualisation without applying excessive force.
  6. Advance the appropriate training endotracheal tube through the oral or nasal route as directed.
  7. Remove the equipment carefully after the exercise and allow the instructor to review technique and procedural sequence.
  8. Clean, dry and store the model according to the supplied manual and institutional infection-control procedure.

Usage Note: This neonate intubation model is intended only for education and simulation. It must not be used for patient treatment. Use only compatible training equipment and approved lubricant where applicable. All practice should be supervised by qualified instructors and should follow recognised neonatal airway-management protocols.

Why Choose This Product from MeddeyGo?

MeddeyGo provides medical simulation products, airway trainers, anatomical models and healthcare equipment for hospitals, medical colleges, nursing institutes and professional procurement teams. Its healthcare-focused catalogue helps buyers select products according to their training objective, clinical discipline and institutional requirements.

Buyers selecting this Neonate Intubation Model can seek product-selection assistance regarding oral and nasal training capability, material, equipment compatibility and supplied configuration. Before placing institutional or bulk orders, procurement teams should confirm the package contents, compatible neonatal tubes, laryngoscope requirements, replacement components and maintenance guidance.

Frequently Asked Questions

1. What procedures can be practised on this neonate intubation model?

The model supports supervised practice of neonatal oral intubation, nasal intubation, laryngoscope handling, airway visualisation, endotracheal tube insertion and basic head positioning. It is intended for simulation training and should be used under qualified neonatal or airway-management instruction.

2. Is the model suitable for neonatal resuscitation training?

Yes, it can support the airway-management component of neonatal resuscitation workshops and simulation programmes. Institutions should confirm that the model meets their course requirements and combine it with appropriate protocols, monitoring scenarios and instructor-led competency assessment.

3. Can learners use a laryngoscope and endotracheal tube?

Yes. The model is designed for practice with a suitable laryngoscope and compatible neonatal endotracheal tubes. Buyers should verify the recommended equipment sizes and whether these accessories are included or need to be purchased separately before beginning training.

4. How should the model be cleaned and maintained?

Remove all training equipment after each session and clean the model according to the supplied instructions. Use only approved cleaning agents and lubricant. Avoid sharp instruments, excessive force and harsh chemicals, then dry the airway thoroughly before protected storage.

5. What should institutions confirm before ordering?

Institutions should confirm oral and nasal intubation capability, material, neck flexibility, airway access, compatible tube sizes and final package contents. They should also verify whether a laryngoscope, tubes, lubricant, carrying case or replacement airway components are supplied separately.