Advanced Anesthesia Workstation for OT & ICU Use
In stock
Share this product
Anesthesia Workstation with Ventilator and 7 Inch TFT Display
The anesthesia workstation available at Medansh is designed for controlled delivery of anesthetic gases and assisted ventilation in equipped operation theatres. This configuration accommodates adult and pediatric applications under the direction of qualified anesthesia professionals.
Designed for clinical flexibility, the system provides VCV, PCV, SIMV, manual and standby ventilation modes. It also supports semi-open, semi-closed and closed breathing circuit systems. The integrated 7-inch colour TFT display presents ventilation settings and monitored values for convenient observation during procedures.
The workstation combines oxygen, nitrous oxide and air flow controls with oxygen flush, pressure monitoring, integrated circle absorber and vaporizer mounting support. Its epoxy-coated frame, two storage drawers and onboard battery backup make it a practical option for organized operation theatre workflows.
Key Features of Anesthesia Workstation
Adult and Pediatric SupportSuitable for adult and pediatric anesthesia applications in appropriately equipped surgical environments. |
Multiple Ventilation ModesSupports VCV, PCV, SIMV, manual and standby modes for different clinical ventilation requirements. |
7 Inch Colour TFT DisplayDisplays ventilation settings, monitoring parameters and related information on a colour screen. |
Integrated Circle AbsorberThe integrated circle absorber system supports carbon dioxide absorption and breathing circuit management. |
Gas Flow ManagementOxygen, nitrous oxide and air flow meter support allows controlled gas flow adjustment during anesthesia delivery. |
Strong Workstation FrameHigh-strength epoxy-coated frame with two storage drawers for equipment organization. |
Technical Specifications
| Specification | Details |
|---|---|
| Patient Application | Pediatric and Adult Patients |
| Tidal Volume | 20 ml – 1500 ml |
| Ventilation Modes | VCV, PCV, SIMV, Manual, Standby |
| Driven Mode | Pneumatically Driven, Electronically Controlled |
| Circuit Modes | Semi Open, Semi Closed, Closed System |
| Display | 7 Inch Colour TFT Screen |
| Lung Mechanics | Lung Mechanics and Loops, P-V and V-F |
| Gas Supply | O2, N2O and Air |
| Flow Meter Type | Five Tube Bobbin Type Flow Meter |
| O2 Flow Range | 0.1–1 L/min and 1–10 L/min |
| N2O Flow Range | 0.1–1 L/min and 1–12 L/min |
| Air Flow Range | 0.1–15 L/min |
| Safety Linkage | O2 and N2O Linkage Device with Hypoxy Guard |
| Oxygen Flush | 25 L/min – 75 L/min |
| Gas Source Pressure | O2, N2O and Air: 0.25 MPa – 0.65 MPa |
| Vaporizer Mount | Select Tec Bar Support, 2 Interlocked Vaporizers |
| Vaporizer Compatibility | Halothane, Isoflurane, Sevoflurane |
| Circle Absorber System | Integrated Circle Absorber with Twin Large Volume CO2 Absorber, Non-Return Respiratory Valve, Expiratory Valve and APL Valve |
| Measured Pressure Values | P Peak, Pmean, Pplat, Pmin, PEEP |
| Measured Ventilation Values | MV, Vt, SPONT, Ftotal, fspn, I:E Ratio 4:1–1:8, Rinsp, Cdyn, FiO2 |
| Alarm Parameters | MV, Pressure, Vte, Rate, FiO2, Battery Low, Battery Discharged, O2 Supply Failure, Apnea, Circuit Occlusion |
| Frame | Rust-Proof Epoxy-Coated High Strength Frame |
| Storage | 2 Big Drawers |
| Pipeline Attachment | For O2 and N2O |
| Yoke Support | 2 Each for O2 and N2O |
| Power Supply | 220V, 50/60Hz |
| Battery Backup | 12V DC, Minimum 120 Minutes |
| Dimensions | 150 x 67 x 60 cm |
| Optional Feature | Basal Flow |
Specifications are based on the supplied product information. Confirm the exact model and final configuration before purchase.
Product Benefits
- Supports controlled anesthesia delivery during surgical procedures.
- Suitable for adult and pediatric anesthesia applications.
- Multiple ventilation modes support different clinical requirements.
- 7-inch colour TFT display makes monitored settings and values easier to read.
- O2, N2O and air flow meter support assists gas delivery management.
- Integrated circle absorber supports breathing circuit management.
- Alarm functionality helps notify staff of monitored conditions requiring attention.
- High-strength frame and storage drawers support organized OT workflow.
Applications and Use Cases
|
Operation Theatres
Designed for controlled anesthesia delivery and respiratory support during surgical procedures. |
Critical Care Environments
Potential use in settings where the model specifications and institutional clinical protocols permit. |
|
Trauma Centres
Supports anesthesia management during emergency surgical procedures. |
Multispecialty Hospitals
Suitable for appropriately equipped hospital surgical departments managing adult and pediatric procedures. |
Who Should Buy This Product?
- Multispecialty hospitals
- Operation theatres and surgical departments
- Anesthesiology departments
- Trauma and emergency surgical centres
- Healthcare facilities equipped for adult and pediatric anesthesia care
- Hospital procurement teams comparing anesthesia workstations
Usage and Safety Guidance
- Use only under the supervision of a trained anesthesiologist or appropriately qualified clinical professional.
- Inspect gas connections, pipeline attachments, yoke connections and electrical supply before use.
- Verify the selected ventilation mode, circuit configuration and alarm settings before every procedure.
- Check vaporizer compatibility and gas supply pressure according to the manufacturer's instructions.
- Continuously monitor the patient's condition during anesthesia administration.
- Maintain emergency airway management and resuscitation equipment according to institutional OT protocols.
- Clean and maintain the workstation according to applicable infection-control procedures.
- Follow the manufacturer's recommended inspection, calibration, preventive maintenance and servicing schedules.
Why Consider This Anesthesia Workstation at Medansh?
This anesthesia workstation brings gas flow management, multiple ventilation modes, oxygen flush functionality, a circle absorber and monitored ventilation parameters together in one integrated configuration.
The compact workstation layout and two storage drawers provide practical space for organizing compatible accessories around the anesthesia station. Its colour TFT display helps clinical teams access relevant settings and monitoring information.
At Medansh.in, healthcare buyers can explore the equipment specifications and assess their suitability for operation theatres, surgical departments and hospital infrastructure requirements.
Before purchasing, confirm the final supplied configuration, installation requirements, compatible accessories, maintenance needs and available service arrangements.
Buying Guidance
When selecting an anesthesia workstation for a hospital or surgical facility, consider the clinical application, patient categories, ventilation requirements and compatibility with the existing operation theatre infrastructure.
Review the available ventilation modes, tidal volume range, gas flow requirements, vaporizer mounting system, oxygen flush, circle absorber configuration and monitoring parameters.
Also check the workstation dimensions, power requirements, battery backup, pipeline connections, training requirements and maintenance provisions before finalizing the purchase.
Confirm whether compatible vaporizers, breathing circuit accessories and other required components are included in the selected product configuration or need to be purchased separately.
Explore Anesthesia Workstation at Medansh
Planning an operation theatre equipment purchase? Explore this anesthesia workstation with multiple ventilation modes, 7-inch colour TFT display and integrated gas flow management features.
Review the technical specifications and choose a configuration aligned with your hospital's clinical and infrastructure requirements.
Frequently Asked Questions
1. What is an anesthesia workstation used for?
An anesthesia workstation is used to deliver anesthetic gases and provide respiratory support during surgical procedures under qualified clinical supervision.
2. Can this anesthesia machine be used for adult and pediatric patients?
Yes. The supplied specifications identify support for adult and pediatric patient applications.
3. What ventilation modes are available?
The workstation supports VCV, PCV, SIMV, manual and standby ventilation modes.
4. What is the tidal volume range?
The specified tidal volume range is 20 ml to 1500 ml.
5. Does this anesthesia workstation have a colour display?
Yes. It includes a 7-inch colour TFT display for reviewing ventilation settings and monitored parameters.
6. What gases does the workstation support?
The workstation supports oxygen (O2), nitrous oxide (N2O) and air supply connections.
7. Does the anesthesia workstation include battery backup?
According to the supplied specifications, it features 12V DC battery backup rated for a minimum of 120 minutes.
8. What are the workstation dimensions?
The specified dimensions are 150 x 67 x 60 cm.
9. Who should operate this anesthesia workstation?
It should be operated only by trained anesthesiologists or appropriately qualified healthcare professionals following the manufacturer's instructions and institutional safety protocols.