Skip to content

India's Trusted Medical Equipment Supplier

Capnograph Monitor Mainstream EtCO2

Save 23%
Regular price
Sale price Rs. 44,200 Regular price Rs. 58,000
Tax included.

In stock

1 Lakh+
Hospitals Served
22,000+
Delivery Pincodes
CE & ISO
Certified Device
EMI
Easy Financing
  • Free Shipping
  • Easy Return

Ask a question

The fields marked * are required.

Capnograph Monitor Mainstream EtCO2

The Capnograph Monitor Mainstream EtCO2 is a compact respiratory monitoring device designed to measure end-tidal carbon dioxide and airway respiration rate using the mainstream method. It is suitable for emergency departments, intensive care units, operating rooms, respiratory departments and clinical monitoring environments.

This capnograph monitor connects with the patient’s respiratory tract through an airway adapter and breathing tube when used with a ventilator or anaesthetic machine. In addition, it supports audible and visual alarms, over-limit alarm, low battery alarm, Adapter Off prompt, zero calibration and atmospheric pressure and temperature compensation.

Key Features

  • Mainstream capnograph monitor for end-tidal CO2 measurement.
  • Supports airway respiration rate monitoring during ventilation workflow.
  • Suitable for adult, child and infant patients as per supplied details.
  • Designed for use with compatible ventilators or anaesthetic machines.
  • Connects through airway adapter and breathing tube setup.
  • Digital display shows EtCO2 value, respiration rate and waveform indication.
  • Audible and visual alarms support quick attention during monitoring.
  • Over-limit alarm supports EtCO2 and respiration rate monitoring alerts.
  • Adapter Off prompt helps users identify connection-related issues.
  • Portable battery operation supports flexible clinical use.

Technical Specifications

Product Type Mainstream Capnograph / EtCO2 Monitor
Measurement Method Mainstream Method
Measured Parameters End-Tidal CO2 and Airway Respiration Rate
Patient Population Adult, Child and Infant Patients
Applicable Areas Emergency Department, ICU, Operating Room and Respiratory Department
Use Requirement Used with Ventilator or Anaesthetic Machine
Patient Connection Connects with Patient Respiratory Tract Through Airway Adapter and Breathing Tube
EtCO2 Measurement Yes
Respiration Rate Measurement Yes
Display Digital Display with EtCO2 Value, Respiration Rate and Waveform Indication
Unit Options Optional Three Units
Alarm Type Audible and Visual Alarm with Silencing Function
Alarm Limit Setting Alarm Limit Can Be Set
Over-Limit Alarm For End-Tidal CO2 and Respiration Rate
Low Battery Alarm Yes
Prompt Function Adapter Off Prompt
Zero Calibration User Can Calibrate Zero by Themselves
Compensation Functions Atmospheric Pressure and Temperature Compensation
Battery Type 2 AAA Dry Batteries
Battery Backup Up to 4 Hours User Time
Warranty 1 Year

Benefits of Capnograph Monitor

This capnograph monitor supports EtCO2 and airway respiration rate observation during ventilation-based monitoring. As a result, clinical teams can review important respiratory values in emergency, ICU, OT and respiratory care settings.

  • Supports continuous EtCO2 and airway respiration rate observation.
  • Mainstream method provides direct measurement through airway adapter setup.
  • Useful across emergency, ICU, operating room and respiratory care workflows.
  • Applicable for adult, child and infant patients as per product details.
  • Audible and visual alarms support timely attention during monitoring.
  • Adapter Off prompt supports better connection awareness during use.
  • Atmospheric pressure and temperature compensation support stable monitoring.
  • Battery-powered design supports up to 4 hours of portable use.

Who Should Buy This?

The Capnograph Monitor Mainstream EtCO2 is suitable for healthcare teams that need focused ventilation monitoring support with a compact device. Moreover, it is useful where airway respiration rate and EtCO2 monitoring are required with compatible ventilator or anaesthesia systems.

  • Emergency departments for ventilation monitoring support.
  • ICU teams for EtCO2 and respiration rate observation.
  • Operating rooms for anaesthesia and procedure-based monitoring workflows.
  • Respiratory departments for airway and ventilation monitoring support.
  • Recovery areas for post-procedure respiratory observation.
  • Hospitals and clinical buyers looking for a compact mainstream capnograph.
  • Critical care teams needing portable EtCO2 monitoring support.

Common Applications

  • Mainstream EtCO2 monitoring
  • Airway respiration rate monitoring
  • Ventilator-based monitoring support
  • Anaesthetic machine monitoring support
  • Emergency department respiratory observation
  • ICU and OT monitoring workflow
  • Recovery area respiratory monitoring
  • Adult, child and infant ventilation monitoring support

How to Use Safely

  • Insert 2 AAA dry batteries and check device readiness before use.
  • Use the device with a compatible ventilator or anaesthetic machine.
  • Connect the device to the patient’s respiratory tract through the airway adapter.
  • Switch on the capnograph and allow it to initialize as per user manual.
  • Check EtCO2 value, airway respiration rate and waveform display during monitoring.
  • Set alarm limits according to clinical protocol and monitoring needs.
  • Respond to audible, visual, low battery, over-limit or Adapter Off alerts.
  • After use, disconnect safely, clean the device exterior and store it properly.

Why Choose This Mainstream Capnograph?

This mainstream capnograph is designed for clinical teams that need focused EtCO2 and airway respiration rate monitoring during ventilator or anaesthesia-based care. In addition, its compact build, digital display, alarm support, Adapter Off prompt and compensation functions make it useful for critical care and respiratory departments.

  • Compact mainstream capnograph for clinical respiratory monitoring.
  • Measures end-tidal CO2 and airway respiration rate.
  • Suitable for use with ventilators and anaesthetic machines.
  • Alarm functions support faster attention to parameter changes.
  • Good choice for ICU, OT, emergency and respiratory care teams.

FAQs


What does this capnograph monitor measure?

This capnograph monitor measures end-tidal carbon dioxide and airway respiration rate using the mainstream method.

What is mainstream EtCO2 monitoring?

Mainstream EtCO2 monitoring measures carbon dioxide directly through an airway adapter placed in the breathing circuit.

Can this capnograph be used for children and infants?

Yes, the supplied details mention use for adult, child and infant patients. Correct adapter and clinical setup should be selected by trained professionals.

Does this capnograph need a ventilator or anaesthetic machine?

Yes, it is designed for use with a compatible ventilator or anaesthetic machine through the airway adapter and breathing tube setup.

What is the battery backup of this device?

This capnograph uses 2 AAA dry batteries and provides up to 4 hours of user time as per supplied details.

Who should operate this capnograph monitor?

This capnograph monitor should be operated by trained healthcare professionals. Readings should be interpreted with patient condition and facility protocol.