CA10S Capnograph Sidestream EtCO2 Monitor

The CA10S Capnograph Sidestream EtCO2 Monitor is a compact and portable monitoring device designed for adult patient monitoring. It helps healthcare professionals observe end-tidal carbon dioxide, respiration rate, SpO2 and pulse rate during clinical monitoring workflows.

This capnograph uses the sidestream method for EtCO2 monitoring through a sampling tube connection. In addition, it provides waveform display, audible and visual alarms, low battery alarm, alarm silence support and Filterline checking prompt, making it suitable for ICU, OT, emergency care, respiratory departments and recovery areas.

Key Features

  • Compact CA10S capnograph for adult patient monitoring.
  • Sidestream EtCO2 monitoring supports ventilation observation.
  • Measures EtCO2, respiration rate, SpO2 and pulse rate.
  • Waveform display helps users review ventilation trends visually.
  • Audible and visual alarms support timely monitoring alerts.
  • Alarm limits can be set for EtCO2, respiration rate, SpO2 and pulse rate.
  • Checking Filterline prompt helps identify sampling line-related checks.
  • Rechargeable lithium battery supports portable clinical use.
  • Up to 8 hours user time supports mobile monitoring workflow.
  • Suitable for emergency departments, ICU, OT, respiratory care and recovery areas.

Technical Specifications

Product Type Capnograph / EtCO2 Monitor
Model CA10S
Measurement Method Sidestream Method
Application Population Adult Patient
Measured Parameters EtCO2, AWRR / Respiration Rate, SpO2 and Pulse Rate
EtCO2 Function End-Tidal CO2 Measurement
Respiration Rate Function Yes
SpO2 Measurement Yes
Pulse Rate Measurement Yes
Display Digital Screen with EtCO2, SpO2, Respiration Rate, Pulse Rate and Waveform Display
Alarm Functions Audible and Visual Alarm, Silencing Function, Over-Limit Alarm and Low Battery Alarm
Alarm Limit Setting EtCO2, Respiration Rate, SpO2 and Pulse Rate Alarm Limits Can Be Set
Prompt Function Checking Filterline Prompt
Zero Calibration User Can Calibrate Zero by Themselves
Compensation Functions Atmospheric Pressure and Temperature Compensation
Power Source Rechargeable Lithium Battery
Battery Backup Up to 8 Hours User Time
Patient Connection Connected to the Nose End of the Patient Through Sampling Tube / Applied Part
Warranty 1 Year

Benefits of CA10S Capnograph

This capnograph supports professional monitoring of ventilation-related values in adult patients. As a result, clinical teams can observe EtCO2, respiration rate, SpO2 and pulse rate from one portable device.

  • Supports EtCO2 monitoring during adult patient observation.
  • Helps healthcare teams monitor respiration rate, SpO2 and pulse rate.
  • Portable design supports emergency, ICU, OT and respiratory care use.
  • Waveform display supports visual monitoring during ventilation observation.
  • Audible and visual alarms support timely attention to parameter changes.
  • Low battery alarm helps prevent unexpected monitoring interruption.
  • Filterline prompt supports better sampling line awareness during use.
  • Rechargeable battery supports up to 8 hours of user time.

Who Should Buy This?

The CA10S Capnograph Sidestream EtCO2 Monitor is suitable for healthcare teams that need portable ventilation monitoring support for adult patients. Moreover, it is useful where EtCO2, SpO2, pulse rate and respiration rate monitoring are required in one device.

  • Emergency departments for adult ventilation observation support.
  • ICU teams for EtCO2, SpO2 and respiration monitoring workflow.
  • Operating rooms for clinical monitoring support during procedures.
  • Respiratory departments for airway and ventilation observation.
  • Recovery areas for post-procedure patient monitoring support.
  • Ambulance and emergency response teams where applicable and protocol-approved.
  • Hospitals and clinical buyers looking for a portable sidestream capnograph.

Common Applications

  • Sidestream EtCO2 monitoring
  • Adult ventilation observation
  • Respiration rate monitoring
  • SpO2 oxygen saturation monitoring
  • Pulse rate monitoring
  • ICU and OT monitoring support
  • Emergency and respiratory care use
  • Recovery area patient observation

How to Use Safely

  • Charge the device properly before use and check battery status.
  • Inspect the sampling tube or Filterline connection before monitoring.
  • Connect the sampling tube near the adult patient’s nasal end as per user manual.
  • Switch on the capnograph and allow the device to initialize.
  • Check EtCO2, respiration rate, SpO2, pulse rate and waveform display.
  • Set alarm limits according to clinical requirement and facility protocol.
  • Use alarm silence only when clinically appropriate.
  • After use, disconnect safely, clean the device exterior and store it properly.

Why Choose This CA10S Capnograph?

This CA10S capnograph is designed for healthcare professionals who need a compact sidestream EtCO2 monitor with additional SpO2 and pulse rate monitoring support. In addition, its waveform view, alarms, rechargeable battery and adult patient monitoring capability make it useful for multiple clinical departments.

  • Portable sidestream capnograph for adult patient monitoring.
  • Measures EtCO2, respiration rate, SpO2 and pulse rate.
  • Waveform display supports clinical review during monitoring.
  • Alarm functions support faster attention to abnormal values.
  • Good choice for ICU, OT, emergency and respiratory care teams.

FAQs


What does the CA10S capnograph measure?

The CA10S capnograph measures EtCO2, respiration rate, SpO2 and pulse rate. It also displays waveform information for monitoring support.

What is sidestream EtCO2 monitoring?

Sidestream EtCO2 monitoring draws a small gas sample through a sampling tube and measures end-tidal carbon dioxide away from the patient connection point.

Where can this capnograph be used?

This capnograph is suitable for emergency departments, ICU, operating rooms, respiratory departments, recovery areas and adult patient monitoring environments.

Does the CA10S capnograph have alarm functions?

Yes, it has audible and visual alarms, alarm silence, over-limit alarm support and low battery alarm. Alarm limits can be set for key parameters.

What is the battery backup?

The device has a rechargeable lithium battery with up to 8 hours user time as per the supplied details.

Who should operate this capnograph?

This capnograph should be operated by trained healthcare professionals. Monitoring values should be interpreted along with the patient’s clinical condition and facility protocol.