{"product_id":"traction-machine-lcd-cervical-lumbar-unit","title":"Traction Machine LCD Cervical Lumbar Unit","description":"\u003cdiv style=\"font-family: Arial, sans-serif; color: #24313a; line-height: 1.6; max-width: 1100px; margin: auto;\"\u003e\n\u003cdiv style=\"background: #f4fbff; border-left: 4px solid #f47b20; padding: 18px 20px; border-radius: 10px; margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 26px; margin: 0 0 10px; line-height: 1.3;\"\u003eTraction Machine LCD Cervical Lumbar Unit\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; margin: 0 0 10px;\"\u003eThe \u003cstrong\u003eCervical \u0026amp; Lumbar Traction Unit LCD Based\u003c\/strong\u003e is a professional physiotherapy \u003cstrong\u003etraction machine\u003c\/strong\u003e designed to support both cervical and lumbar traction therapy in clinical rehabilitation environments. It is suitable for physiotherapy centres, hospitals, orthopedic rehabilitation departments, pain management clinics, neuro-rehabilitation units, sports injury clinics and therapy setups.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin: 0;\"\u003eThis LCD based traction machine supports continuous and intermittent traction with static, intermittent and harmonic modes. The menu-driven LCD interface, soft touch membrane keys and micro-controller based operation help therapists set traction force, hold time, rest time, treatment mode and program number more conveniently during daily clinical workflow.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 8px;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003eLCD based traction machine for cervical and lumbar therapy support.\u003c\/li\u003e\n\u003cli\u003eSupports continuous and intermittent traction therapy workflow.\u003c\/li\u003e\n\u003cli\u003eStatic, intermittent and harmonic modes for different therapy protocols.\u003c\/li\u003e\n\u003cli\u003eMicro-controller based system supports consistent treatment settings.\u003c\/li\u003e\n\u003cli\u003eTraction force range from 5 kg to 45 kg in 12 steps.\u003c\/li\u003e\n\u003cli\u003eForce can be extended up to 90 kg with traction doubler.\u003c\/li\u003e\n\u003cli\u003eSoft touch membrane keys support comfortable operation by therapists.\u003c\/li\u003e\n\u003cli\u003eProgram memory allows selected user parameters to be saved and recalled.\u003c\/li\u003e\n\u003cli\u003ePatient interrupt switch provides buzzer and visual indication for safety support.\u003c\/li\u003e\n\u003cli\u003eHeavy duty DC motor supports smooth and noiseless operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 10px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003ePhysiotherapy Traction Unit \/ Cervical Lumbar Traction Machine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eLCD Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eOperation Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eMenu Driven Operation with Soft Touch Membrane Keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eTraction Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eContinuous and Intermittent Traction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eModes\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eStatic, Intermittent, Harmonic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eTraction Force\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e5 kg to 45 kg in 12 Steps; up to 90 kg with Doubler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eHold Time\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e1 Second to 99 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eRest Time\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e1 Second to 99 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eParameter Setting\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eWeight and Whole Time \/ Rest Time Can Be Set with 1 Unit Step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eMotor\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eHeavy Duty DC Motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eAlarm\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eAt End of Treatment and During Activation of Patient Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003ePatient Safety\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003ePatient Interrupt with Buzzer and Visual Indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003ePower Required\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e220V, 50Hz; 110V Available on Request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eSuitable For\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eHospitals, Physiotherapy Clinics, Rehabilitation Centres and Orthopedic Therapy Setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 8px;\"\u003eBenefits of Traction Machine\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eThis traction machine supports cervical and lumbar traction therapy in professional physiotherapy setups. It helps therapists deliver controlled traction force, select therapy modes and manage treatment timing according to patient condition and clinical protocol.\u003c\/p\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003eSupports both cervical and lumbar traction therapy workflow.\u003c\/li\u003e\n\u003cli\u003eLCD menu-driven interface helps simplify parameter selection.\u003c\/li\u003e\n\u003cli\u003eMicro-controller based system supports repeatable traction settings.\u003c\/li\u003e\n\u003cli\u003eStatic, intermittent and harmonic modes support different treatment needs.\u003c\/li\u003e\n\u003cli\u003eProgram memory helps save and recall commonly used parameters.\u003c\/li\u003e\n\u003cli\u003ePatient interrupt switch supports safer therapy workflow.\u003c\/li\u003e\n\u003cli\u003eSmooth and noiseless motor operation supports patient comfort.\u003c\/li\u003e\n\u003cli\u003eForce range up to 90 kg with doubler supports broader clinical requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 8px;\"\u003eWho Should Buy This?\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eThe Cervical \u0026amp; Lumbar Traction Unit LCD Based is suitable for healthcare and therapy facilities that need a reliable traction machine for controlled cervical and lumbar traction treatment. It is useful where accurate force setting, treatment timing and patient safety support are important.\u003c\/p\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysiotherapy centres\u003c\/strong\u003e for daily cervical and lumbar traction therapy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHospitals\u003c\/strong\u003e with physiotherapy and rehabilitation departments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrthopedic rehabilitation centres\u003c\/strong\u003e for spinal traction therapy support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePain management clinics\u003c\/strong\u003e for supervised traction-based therapy sessions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSports injury clinics\u003c\/strong\u003e for guided neck and back rehabilitation support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeuro-rehabilitation units\u003c\/strong\u003e for selected therapy protocols under supervision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHealthcare buyers\u003c\/strong\u003e looking for an LCD based traction machine.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 8px;\"\u003eCommon Applications\u003c\/h2\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003eCervical traction therapy\u003c\/li\u003e\n\u003cli\u003eLumbar traction therapy\u003c\/li\u003e\n\u003cli\u003eSpinal decompression support\u003c\/li\u003e\n\u003cli\u003ePhysiotherapy rehabilitation programs\u003c\/li\u003e\n\u003cli\u003eOrthopedic therapy workflow\u003c\/li\u003e\n\u003cli\u003ePosture-related discomfort management under supervision\u003c\/li\u003e\n\u003cli\u003eSports injury rehabilitation support\u003c\/li\u003e\n\u003cli\u003eSupervised pain management therapy sessions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 8px;\"\u003eHow to Use Safely\u003c\/h2\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003ePlace the traction unit on a stable surface and connect it to the appropriate power supply.\u003c\/li\u003e\n\u003cli\u003eAssess the patient’s condition before deciding cervical or lumbar traction suitability.\u003c\/li\u003e\n\u003cli\u003ePosition the patient correctly using the required traction setup.\u003c\/li\u003e\n\u003cli\u003eSelect static, intermittent or harmonic mode using the LCD interface.\u003c\/li\u003e\n\u003cli\u003eSet traction force, hold time, rest time and treatment duration as per clinical requirement.\u003c\/li\u003e\n\u003cli\u003eProvide the patient safety switch and explain how to interrupt treatment if discomfort occurs.\u003c\/li\u003e\n\u003cli\u003eStart treatment and monitor patient response throughout the session.\u003c\/li\u003e\n\u003cli\u003eAfter treatment, reduce force safely and clean contact components as per clinic protocol.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 8px;\"\u003eWhy Choose This LCD Based Traction Unit?\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eThis LCD based cervical and lumbar traction unit is designed for physiotherapy teams that need reliable traction equipment with multiple therapy modes, programmable settings, patient interrupt support and smooth motor performance. It supports professional therapy workflow for both neck and lower back traction applications.\u003c\/p\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003eLCD interface supports easier treatment setting and monitoring.\u003c\/li\u003e\n\u003cli\u003eStatic, intermittent and harmonic modes provide therapy flexibility.\u003c\/li\u003e\n\u003cli\u003eMicro-controller operation supports consistent traction delivery.\u003c\/li\u003e\n\u003cli\u003ePatient interrupt switch improves safety during therapy sessions.\u003c\/li\u003e\n\u003cli\u003eGood choice for physiotherapy clinics, hospitals and rehabilitation centres.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 10px;\"\u003eFAQs\u003c\/h2\u003e\n\u003ch3 style=\"color: #f47b20; font-size: 17px; margin: 0 0 4px;\"\u003eWhat is a traction machine used for?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eA traction machine is used to support supervised cervical and lumbar traction therapy by applying controlled traction force under professional guidance.\u003c\/p\u003e\n\u003ch3 style=\"color: #f47b20; font-size: 17px; margin: 0 0 4px;\"\u003eWhat traction modes are available?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eThis unit supports static, intermittent and harmonic traction modes for different physiotherapy protocols.\u003c\/p\u003e\n\u003ch3 style=\"color: #f47b20; font-size: 17px; margin: 0 0 4px;\"\u003eWhat is the traction force range?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eThe traction force range is 5 kg to 45 kg in 12 steps. With a traction doubler, it can be extended up to 90 kg.\u003c\/p\u003e\n\u003ch3 style=\"color: #f47b20; font-size: 17px; margin: 0 0 4px;\"\u003eDoes this traction unit have patient safety support?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eYes, it includes a patient interrupt switch with buzzer and visual indication during therapy.\u003c\/p\u003e\n\u003ch3 style=\"color: #f47b20; font-size: 17px; margin: 0 0 4px;\"\u003eIs this suitable for physiotherapy clinics?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eYes, this traction machine is suitable for physiotherapy clinics, hospitals, rehabilitation centres and orthopedic therapy setups.\u003c\/p\u003e\n\u003ch3 style=\"color: #f47b20; font-size: 17px; margin: 0;\"\u003eWho should operate this traction machine?\u003c\/h3\u003e\n\u003cp style=\"margin: 4px 0 0;\"\u003eThis traction machine should be operated by trained physiotherapists, rehabilitation professionals, orthopedic therapy staff or authorized healthcare users.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Medansh","offers":[{"title":"Default Title","offer_id":53684302610705,"sku":"MSH1004159","price":18200.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0749\/1482\/4465\/files\/cervical_lumber_traction.webp?v=1781784587","url":"https:\/\/medansh.in\/products\/traction-machine-lcd-cervical-lumbar-unit","provider":"Medansh","version":"1.0","type":"link"}