{"product_id":"senstim-peripherial-nerve-stimulator-nerve-locator-pns-machine","title":"Senstim Peripherial Nerve Stimulator | Nerve Locator PNS Machine","description":"\u003cdiv style=\"font-family: Arial, Helvetica, sans-serif; color: #222222; line-height: 1.65; font-size: 15px;\"\u003e\n\n  \u003ch2 style=\"color: #006093; margin: 0 0 12px;\"\u003eSenstim Peripheral Nerve Stimulator | Nerve Locator PNS Machine\u003c\/h2\u003e\n\n  \u003cp\u003e\n    The \u003cstrong\u003eSenstim Peripheral Nerve Stimulator\u003c\/strong\u003e is a compact nerve locator PNS machine designed for professional clinical and anaesthesia use. It supports controlled electrical pulse delivery for peripheral nerve location during suitable medical procedures. It is suitable for hospitals, operation theatres, anaesthesia departments, surgical centres, pain management clinics, medical colleges, and clinical setups where trained users require nerve stimulation support.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    This \u003cstrong style=\"color: #fc6c15;\"\u003enerve locator PNS machine\u003c\/strong\u003e offers adjustable pulse amplitude from \u003cstrong\u003e0.2mA to 5.0mA\u003c\/strong\u003e, switchable frequency of \u003cstrong\u003e1Hz or 2Hz\u003c\/strong\u003e, and a large \u003cstrong\u003e3-digit 7-segment display\u003c\/strong\u003e for clear impulse current reading. The default frequency is 1Hz, and the device allows frequency selection when required by the trained clinical user.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    The device includes LED indicators and beep tone support for better operational feedback. The yellow pulse LED indicates pulse delivery when the circuit is closed, while the red battery LED indicates low battery condition. It operates on a \u003cstrong\u003e9V battery\u003c\/strong\u003e and should be used only by trained doctors, anaesthesia professionals, qualified clinical staff, or authorized healthcare users according to the user manual and hospital protocol.\n  \u003c\/p\u003e\n\n  \u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eKey Features\u003c\/h3\u003e\n\n  \u003cul style=\"padding-left: 20px; margin-top: 8px;\"\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003ePeripheral Nerve Stimulator:\u003c\/strong\u003e Designed to support clinical nerve location workflow during suitable procedures.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eAdjustable Pulse Amplitude:\u003c\/strong\u003e Supports current adjustment from 0.2mA to 5.0mA for controlled stimulation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eSwitchable Frequency:\u003c\/strong\u003e Frequency can be changed between 1Hz and 2Hz according to clinical requirement.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eLarge Digital Display:\u003c\/strong\u003e 3-digit 7-segment display shows impulse current clearly for easier monitoring.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003ePulse LED Indicator:\u003c\/strong\u003e Yellow LED flashes when pulse delivery occurs in a closed circuit.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eBattery LED Indicator:\u003c\/strong\u003e Red LED flashing indicates low battery condition.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eBeep Tone Support:\u003c\/strong\u003e Beep tone is heard during self-test and pulse delivery when the circuit is closed.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eBattery Operated:\u003c\/strong\u003e Works with a 9V battery, Type 6LR–61 or 6F22, for portable clinical use.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\n  \u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px; font-size: 15px;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eSenstim Peripheral Nerve Stimulator\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eNerve Locator PNS Machine\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003ePeripheral Nerve Stimulator \/ Clinical Nerve Locator\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003ePulse Amplitude\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e0.2mA to 5.0mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003ePulse Width\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e0.1 m sec\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003ePulse Frequency\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e1Hz or 2Hz Switchable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eDefault Frequency\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e1Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e0 to 5K Ohms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e3 Digit 7 Segment Large Display\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e0.01mA or 0.1mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e9V, Type 6LR–61 or 6F22\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eBattery Indication\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eRed LED Flashing Indicates Low Battery\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003ePulse Indication\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eYellow LED Flashing with Beep Sound for Each Pulse When Circuit is Closed\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eSuitable For\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eHospitals, Operation Theatres, Anaesthesia Departments and Clinical Nerve Location Use\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eProduct Benefits\u003c\/h3\u003e\n\n  \u003cul style=\"padding-left: 20px; margin-top: 8px;\"\u003e\n    \u003cli\u003eSupports peripheral nerve location workflow during suitable clinical procedures.\u003c\/li\u003e\n    \u003cli\u003eAdjustable current range helps trained users select required pulse amplitude.\u003c\/li\u003e\n    \u003cli\u003eLarge digital display makes impulse current value easy to read.\u003c\/li\u003e\n    \u003cli\u003e1Hz and 2Hz frequency options provide practical clinical flexibility.\u003c\/li\u003e\n    \u003cli\u003eLED indicators help monitor pulse delivery and battery condition.\u003c\/li\u003e\n    \u003cli\u003eBattery-operated design makes the device portable and convenient for clinical use.\u003c\/li\u003e\n    \u003cli\u003eBeep tone support helps confirm pulse delivery when the circuit is closed.\u003c\/li\u003e\n    \u003cli\u003eCompact format supports use in anaesthesia departments, OTs, and clinical procedure areas.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eApplications\u003c\/h3\u003e\n\n  \u003cp\u003e\n    The \u003cstrong\u003eSenstim Peripheral Nerve Stimulator\u003c\/strong\u003e is suitable for peripheral nerve location support, anaesthesia procedure support, clinical nerve stimulation use, operation theatre workflow, pain management clinic support, training and teaching setups under supervision, and hospital or surgical centre use.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    It can be used by trained healthcare professionals in suitable clinical environments where controlled nerve stimulation is required. Final use depends on procedure type, clinical protocol, patient condition, operator training, and hospital guidelines.\n  \u003c\/p\u003e\n\n  \u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eHow to Use\u003c\/h3\u003e\n\n  \u003col style=\"padding-left: 20px; margin-top: 8px;\"\u003e\n    \u003cli\u003eInsert the recommended 9V battery and confirm that the device powers on properly.\u003c\/li\u003e\n    \u003cli\u003ePerform the required self-check according to the user manual and facility protocol.\u003c\/li\u003e\n    \u003cli\u003eConnect compatible clinical cables or probe as per procedure requirement.\u003c\/li\u003e\n    \u003cli\u003eSelect the required frequency, either 1Hz or 2Hz, according to clinical need.\u003c\/li\u003e\n    \u003cli\u003eAdjust pulse amplitude gradually within the 0.2mA to 5.0mA range as directed by the trained operator.\u003c\/li\u003e\n    \u003cli\u003eMonitor the display, yellow pulse LED, beep tone, and patient response during use.\u003c\/li\u003e\n    \u003cli\u003eStop use if any abnormal response, device issue, or clinical concern occurs.\u003c\/li\u003e\n    \u003cli\u003eAfter use, switch off the device and store it safely according to hospital equipment protocol.\u003c\/li\u003e\n  \u003c\/ol\u003e\n\n  \u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eWhy Choose Senstim Peripheral Nerve Stimulator?\u003c\/h3\u003e\n\n  \u003cp\u003e\n    The \u003cstrong\u003eSenstim Peripheral Nerve Stimulator\u003c\/strong\u003e is suitable for clinical users who need a compact nerve locator with adjustable current, clear digital display, pulse indication, and battery-operated portability. Its simple controls and readable display make it practical for professional medical environments.\n  \u003c\/p\u003e\n\n  \u003cp\u003e\n    With pulse amplitude from 0.2mA to 5.0mA, switchable 1Hz\/2Hz frequency, low battery indication, and beep tone support, this PNS machine provides essential features required for trained clinical nerve stimulation workflow. Buyers should confirm compatible probe, cable requirements, battery type, user training, and facility protocol before use.\n  \u003c\/p\u003e\n\n  \u003cp style=\"background: #fff7f0; padding: 12px; border-left: 4px solid #fc6c15; margin-top: 14px;\"\u003e\n    \u003cstrong\u003eProfessional Use Note:\u003c\/strong\u003e This nerve stimulator is intended for trained clinical use only. It should not be used by untrained users or for self-treatment. Always follow the user manual, hospital protocol, and professional clinical guidance.\n  \u003c\/p\u003e\n\n  \u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eFAQs\u003c\/h3\u003e\n\n  \u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e1. What is Senstim Peripheral Nerve Stimulator used for?\u003c\/h4\u003e\n  \u003cp\u003e\n    It is used by trained healthcare professionals for peripheral nerve location support during suitable clinical procedures.\n  \u003c\/p\u003e\n\n  \u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e2. What is the pulse amplitude range?\u003c\/h4\u003e\n  \u003cp\u003e\n    The pulse amplitude range is 0.2mA to 5.0mA.\n  \u003c\/p\u003e\n\n  \u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e3. What frequency options are available?\u003c\/h4\u003e\n  \u003cp\u003e\n    The device supports 1Hz and 2Hz switchable frequency. The default frequency is 1Hz.\n  \u003c\/p\u003e\n\n  \u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e4. What type of display does it have?\u003c\/h4\u003e\n  \u003cp\u003e\n    It has a 3-digit 7-segment large display for impulse current reading.\n  \u003c\/p\u003e\n\n  \u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e5. What battery does it use?\u003c\/h4\u003e\n  \u003cp\u003e\n    It uses a 9V battery, Type 6LR–61 or 6F22.\n  \u003c\/p\u003e\n\n  \u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e6. Does it have low battery indication?\u003c\/h4\u003e\n  \u003cp\u003e\n    Yes, red LED flashing indicates low battery condition.\n  \u003c\/p\u003e\n\n  \u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e7. Who should operate this device?\u003c\/h4\u003e\n  \u003cp\u003e\n    It should be operated only by trained doctors, anaesthesia professionals, qualified clinical staff, or authorized healthcare users.\n  \u003c\/p\u003e\n\n\u003c\/div\u003e\n","brand":"Medansh","offers":[{"title":"Default Title","offer_id":53706152935697,"sku":"MSH1006973","price":32240.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0749\/1482\/4465\/files\/pns_machine.webp?v=1782374598","url":"https:\/\/medansh.in\/products\/senstim-peripherial-nerve-stimulator-nerve-locator-pns-machine","provider":"Medansh","version":"1.0","type":"link"}