{"product_id":"automatic-plc-rectangular-autoclave-machine","title":"Automatic PLC Rectangular Autoclave Machine SS 304","description":"\u003cdiv style=\"font-family: Arial, sans-serif; color: #24313a; line-height: 1.6; max-width: 1100px; margin: auto;\"\u003e\n\u003cdiv style=\"background: #f4fbff; border-left: 4px solid #f47b20; padding: 18px 20px; border-radius: 10px; margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 26px; margin: 0 0 10px; line-height: 1.3;\"\u003eAutomatic PLC Rectangular Autoclave Machine SS 304\u003c\/h2\u003e\n\u003cp style=\"font-size: 16px; margin: 0 0 10px;\"\u003eThe \u003cstrong\u003eAutomatic PLC Rectangular Autoclave Machine SS 304\u003c\/strong\u003e is a professional steam sterilization system designed for hospitals, CSSD areas, laboratories, pharmaceutical facilities, diagnostic centres and research departments. It supports sterilization of compatible surgical instruments, laboratory glassware, vessels, filters, liquids, machine parts and reusable medical equipment.\u003c\/p\u003e\n\u003cp style=\"font-size: 16px; margin: 0;\"\u003eThis \u003cstrong\u003eautoclave machine\u003c\/strong\u003e uses automatic PLC control to support consistent sterilization cycles and better workflow handling. In addition, its triple-walled rectangular chamber, SS 304 stainless steel construction and self-locking safety door make it suitable for demanding sterilization environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 8px;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003eAutomatic PLC rectangular autoclave machine for professional steam sterilization use.\u003c\/li\u003e\n\u003cli\u003eTriple-walled chamber design supports stable heat retention and bulk sterilization handling.\u003c\/li\u003e\n\u003cli\u003eSS 304 stainless steel construction for pressure vessel, boiler, jacket, lid and chamber parts.\u003c\/li\u003e\n\u003cli\u003ePositive self-locking safety door helps prevent opening while the chamber is under pressure.\u003c\/li\u003e\n\u003cli\u003eRadial locking lid supports secure chamber sealing during sterilization cycles.\u003c\/li\u003e\n\u003cli\u003eAutomatic pressure control, pressure monitoring and low water cut-off support safer operation.\u003c\/li\u003e\n\u003cli\u003eMoisture trap and vacuum breaker help manage chamber discharge and pressure balance.\u003c\/li\u003e\n\u003cli\u003eAvailable in single-door and double-door options for different sterilization room workflows.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 10px;\"\u003eAvailable Variants\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eVariant\u003c\/th\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eSize\u003c\/th\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eCapacity\u003c\/th\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eDoor Type\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eVariant 1\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e24 x 24 x 48 Inch\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e430 Ltr\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eSingle Door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eVariant 2\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e24 x 24 x 48 Inch\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e430 Ltr\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eDouble Door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eVariant 3\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e24 x 24 x 60 Inch\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e510 Ltr\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eSingle Door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eVariant 4\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e24 x 24 x 60 Inch\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e510 Ltr\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eDouble Door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eVariant 5\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e36 x 36 x 60 Inch\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e925 Ltr\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eSingle Door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eVariant 6\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e36 x 36 x 60 Inch\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e925 Ltr\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eDouble Door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 10px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eHorizontal Rectangular Autoclave \/ Steam Sterilizer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eOperation\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eAutomatic PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eChamber Type\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eTriple-Walled Rectangular Chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eInner Dimensions\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e18 x 18 x 36 Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eReference Capacity\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e175 Ltr; larger capacities available as per selected variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eSterilizing Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e1.2 kgf\/cm² \/ 15 PSI at 121°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eOperating Pressure\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e15 PSI to 20 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003ePressure Gauge\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e0-2.1 kgf\/cm² \/ 30 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eDisplay\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eDial Thermometer standard with the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003ePressure Vessel\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eStainless Steel SS 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eBoiler\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eStainless Steel SS 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eJacket, Lid \u0026amp; External Wall\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eStainless Steel SS 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eStand and Support Ring\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eMild Steel, Powder Coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eGasket\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003eSilicon Rubber \/ Neoprene Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e220\/230V AC, 50\/60Hz or 430\/440V, 3 Phase Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 10px; border: 1px solid #dce8ee; background: #f4fbff; color: #075f91;\"\u003eRecommended Electrical Supply\u003c\/th\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dce8ee;\"\u003e440V, 3 Phase, 50Hz AC Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 8px;\"\u003eBenefits of Automatic PLC Rectangular Autoclave Machine\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eThis automatic PLC autoclave machine helps facilities manage controlled steam sterilization for larger compatible loads. As a result, it is useful for departments that need repeatable cycles, reliable safety support and better chamber space utilization.\u003c\/p\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003eSupports sterilization workflow for hospitals, laboratories, pharma units and CSSD areas.\u003c\/li\u003e\n\u003cli\u003eAutomatic PLC operation helps improve cycle control and process consistency.\u003c\/li\u003e\n\u003cli\u003eTriple-walled structure helps reduce thermal loss and supports stable chamber conditions.\u003c\/li\u003e\n\u003cli\u003eSS 304 stainless steel construction supports durability and corrosion resistance.\u003c\/li\u003e\n\u003cli\u003eSelf-locking safety door helps prevent accidental opening under pressure.\u003c\/li\u003e\n\u003cli\u003eMoisture trap and vacuum breaker support chamber discharge and pressure management.\u003c\/li\u003e\n\u003cli\u003eSingle-door and double-door options support different workflow layouts.\u003c\/li\u003e\n\u003cli\u003eMultiple capacity options support higher sterilization workload requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 8px;\"\u003eWho Should Buy This?\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eThe Automatic PLC Rectangular Autoclave Machine SS 304 is suitable for professional facilities that need a high-capacity steam sterilizer with automated control and strong safety features. Moreover, it is useful where clean-side workflow, larger load handling and process control are important.\u003c\/p\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eHospitals and CSSD departments\u003c\/strong\u003e for controlled sterilization workflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation theatres\u003c\/strong\u003e for compatible surgical instrument processing support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePharmaceutical facilities\u003c\/strong\u003e for compatible vessels, filters, liquids and process items.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic laboratories\u003c\/strong\u003e for routine sterilization room use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicrobiology and research labs\u003c\/strong\u003e for compatible glassware and lab tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMedical colleges\u003c\/strong\u003e for institutional sterilization and training setups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial sterilization areas\u003c\/strong\u003e for approved steam-compatible items.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 8px;\"\u003eCommon Applications\u003c\/h2\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003eSterilization of compatible surgical instruments\u003c\/li\u003e\n\u003cli\u003eLaboratory glassware sterilization\u003c\/li\u003e\n\u003cli\u003eVessels, filters and liquid sterilization where compatible\u003c\/li\u003e\n\u003cli\u003eMachine parts sterilization where steam-safe\u003c\/li\u003e\n\u003cli\u003eHospital CSSD and sterilization room workflow\u003c\/li\u003e\n\u003cli\u003eOperation theatre instrument processing support\u003c\/li\u003e\n\u003cli\u003ePharmaceutical and laboratory sterilization support\u003c\/li\u003e\n\u003cli\u003eResearch and microbiology lab use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 8px;\"\u003eHow to Use Safely\u003c\/h2\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003eInstall the autoclave in a suitable sterilization area with proper electrical supply and ventilation.\u003c\/li\u003e\n\u003cli\u003eInspect the chamber, door, gasket, pressure gauge, water level indicator and safety valves before use.\u003c\/li\u003e\n\u003cli\u003eLoad compatible items in approved packs or containers without blocking steam circulation.\u003c\/li\u003e\n\u003cli\u003eClose the door and ensure the self-locking safety mechanism is properly engaged.\u003c\/li\u003e\n\u003cli\u003eSelect the appropriate PLC cycle settings according to load type and facility protocol.\u003c\/li\u003e\n\u003cli\u003eAllow the unit to complete sterilization, exhaust, drying if selected and cooling phases.\u003c\/li\u003e\n\u003cli\u003eOpen the chamber only after pressure is safely released and the cycle is complete.\u003c\/li\u003e\n\u003cli\u003eUnload processed items carefully and clean the chamber as per user manual instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 8px;\"\u003eWhy Choose This Automatic PLC Rectangular Autoclave?\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eThis automatic PLC rectangular autoclave is designed for facilities that need controlled operation, durable construction and dependable steam sterilization performance. In addition, the triple-walled rectangular chamber and SS 304 build make it suitable for demanding healthcare, pharmaceutical, diagnostic and research settings.\u003c\/p\u003e\n\u003cul style=\"margin: 0; padding-left: 20px;\"\u003e\n\u003cli\u003eAutomatic PLC control supports repeatable sterilization cycles.\u003c\/li\u003e\n\u003cli\u003eRectangular chamber supports better use of internal loading space.\u003c\/li\u003e\n\u003cli\u003eSS 304 pressure vessel, boiler, lid, jacket and chamber parts support durability.\u003c\/li\u003e\n\u003cli\u003eSelf-locking safety door helps improve operational safety.\u003c\/li\u003e\n\u003cli\u003eGood choice for hospitals, CSSD areas, pharma units, labs and institutional buyers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 style=\"color: #075f91; font-size: 22px; margin: 0 0 10px;\"\u003eFAQs\u003c\/h2\u003e\n\u003cbr\u003e\n\u003ch3 style=\"color: #f47b20; font-size: 17px; margin: 0 0 4px;\"\u003eWhat is an autoclave machine used for?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eAn autoclave machine is used for steam sterilization of compatible surgical instruments, laboratory glassware, vessels, filters, liquids, machine parts and reusable medical items.\u003c\/p\u003e\n\u003ch3 style=\"color: #f47b20; font-size: 17px; margin: 0 0 4px;\"\u003eWhat is the benefit of automatic PLC control?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eAutomatic PLC control helps manage sterilization cycle functions more systematically. Therefore, it supports process consistency, user convenience and controlled workflow when operated by trained users.\u003c\/p\u003e\n\u003ch3 style=\"color: #f47b20; font-size: 17px; margin: 0 0 4px;\"\u003eWhat is the benefit of a rectangular chamber?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eA rectangular chamber helps improve internal loading space and chamber utilization. As a result, it is useful for larger loads in hospitals, laboratories and pharmaceutical facilities.\u003c\/p\u003e\n\u003ch3 style=\"color: #f47b20; font-size: 17px; margin: 0 0 4px;\"\u003eWhat capacities are available?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eThe supplied specifications mention a 175 Ltr reference capacity. Additional variants include 430 Ltr, 510 Ltr and 925 Ltr in single-door and double-door configurations.\u003c\/p\u003e\n\u003ch3 style=\"color: #f47b20; font-size: 17px; margin: 0 0 4px;\"\u003eWhat material is used in this autoclave?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 10px;\"\u003eThe pressure vessel, boiler, jacket, lid, inner chamber and external wall are listed as SS 304 stainless steel, supporting durability and professional sterilization use.\u003c\/p\u003e\n\u003ch3 style=\"color: #f47b20; font-size: 17px; margin: 0;\"\u003eWho should operate this autoclave machine?\u003c\/h3\u003e\n\u003cp style=\"margin: 4px 0 0;\"\u003eThis autoclave machine should be operated by trained sterilization staff, laboratory personnel, pharmaceutical operators, biomedical technicians or authorized users because it works with steam, pressure, heat and electrical systems.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Medansh","offers":[{"title":"Single Door \/ 24 x 24 x 48 Inch 430 Ltr","offer_id":53671842119953,"sku":"MSH1006563","price":799490.0,"currency_code":"INR","in_stock":true},{"title":"Single Door \/ 24 x 24 x 60 Inch 510 Ltr","offer_id":53671842152721,"sku":"MSH1006565","price":879490.0,"currency_code":"INR","in_stock":true},{"title":"Single Door \/ 36 x 36 x 60 Inch 925 Ltr","offer_id":53671842185489,"sku":"MSH1006567","price":999490.0,"currency_code":"INR","in_stock":true},{"title":"Double Door \/ 24 x 24 x 48 Inch 430 Ltr","offer_id":53671842218257,"sku":"MSH1006564","price":899490.0,"currency_code":"INR","in_stock":true},{"title":"Double Door \/ 24 x 24 x 60 Inch 510 Ltr","offer_id":53671842251025,"sku":"MSH1006566","price":979490.0,"currency_code":"INR","in_stock":true},{"title":"Double Door \/ 36 x 36 x 60 Inch 925 Ltr","offer_id":53671842283793,"sku":"MSH1006568","price":1099490.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0749\/1482\/4465\/files\/autocalve_horizontal_price_use.webp?v=1781517946","url":"https:\/\/medansh.in\/products\/automatic-plc-rectangular-autoclave-machine","provider":"Medansh","version":"1.0","type":"link"}