{"product_id":"audiometer-machine-elite-101","title":"Elite 101 Diagnostic Audiometer Machine for ENT \u0026 Hearing Tests","description":"\u003cdiv style=\"font-family: Arial,Helvetica,sans-serif; color: #263445; line-height: 1.65; background: #f8fbfd; border: 1px solid #dceaf3; border-radius: 18px; overflow: hidden; max-width: 100%;\"\u003e\n\u003c!-- TOP USP CARDS --\u003e\n\u003cdiv style=\"padding: 24px 20px 12px; background: #ffffff;\"\u003e\n\u003cdiv style=\"background: #edf6fb; border: 1px solid #cfe2ed; border-radius: 18px; padding: 20px;\"\u003e\n\u003ch2 style=\"color: #006093; font-size: 20px; line-height: 1.4; text-align: center; margin: 0 0 17px;\"\u003eElite 101 Audiometer: Clinical Highlights\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(145px,1fr)); gap: 12px;\"\u003e\n\u003cdiv style=\"background: #ffffff; border: 1px solid #d9e7ef; border-radius: 14px; padding: 15px 10px; text-align: center;\"\u003e\n\u003cdiv style=\"width: 52px; height: 52px; border-radius: 50%; margin: 0 auto 9px; background: #eaf5ff; color: #006093; display: flex; align-items: center; justify-content: center; font-size: 17px; font-weight: bold;\"\u003e2 CH\u003c\/div\u003e\n\u003cstrong style=\"display: block; color: #006093; font-size: 15px;\"\u003e2-Channel System\u003c\/strong\u003e \u003cspan style=\"color: #66727a; font-size: 13px;\"\u003eDiagnostic Audiometry\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #ffffff; border: 1px solid #d9e7ef; border-radius: 14px; padding: 15px 10px; text-align: center;\"\u003e\n\u003cdiv style=\"width: 52px; height: 52px; border-radius: 50%; margin: 0 auto 9px; background: #fff1e8; color: #ad5726; display: flex; align-items: center; justify-content: center; font-size: 15px; font-weight: bold;\"\u003e8kHz\u003c\/div\u003e\n\u003cstrong style=\"display: block; color: #006093; font-size: 15px;\"\u003e125–8000 Hz\u003c\/strong\u003e \u003cspan style=\"color: #66727a; font-size: 13px;\"\u003eFrequency Range\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #ffffff; border: 1px solid #d9e7ef; border-radius: 14px; padding: 15px 10px; text-align: center;\"\u003e\n\u003cdiv style=\"width: 52px; height: 52px; border-radius: 50%; margin: 0 auto 9px; background: #eaf5ff; color: #006093; display: flex; align-items: center; justify-content: center; font-size: 15px; font-weight: bold;\"\u003ePTA\u003c\/div\u003e\n\u003cstrong style=\"display: block; color: #006093; font-size: 15px;\"\u003eMultiple Tests\u003c\/strong\u003e \u003cspan style=\"color: #66727a; font-size: 13px;\"\u003ePure Tone \u0026amp; Speech\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #ffffff; border: 1px solid #d9e7ef; border-radius: 14px; padding: 15px 10px; text-align: center;\"\u003e\n\u003cdiv style=\"width: 52px; height: 52px; border-radius: 50%; margin: 0 auto 9px; background: #fff1e8; color: #ad5726; display: flex; align-items: center; justify-content: center; font-size: 16px; font-weight: bold;\"\u003e3.5\u003c\/div\u003e\n\u003cstrong style=\"display: block; color: #006093; font-size: 15px;\"\u003eTFT Display\u003c\/strong\u003e \u003cspan style=\"color: #66727a; font-size: 13px;\"\u003eRotary Controls\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- PRODUCT OVERVIEW --\u003e\n\u003cdiv style=\"padding: 14px 25px 25px; background: #ffffff;\"\u003e\n\u003ch2 style=\"color: #006093; font-size: 24px; line-height: 1.35; margin: 0 0 13px;\"\u003eElite 101 Audiometer Machine for Professional Hearing Tests\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003eThe \u003cstrong\u003eElite 101 Audiometer Machine\u003c\/strong\u003e is a compact, two-channel device for professional hearing assessment. It helps audiologists and ENT teams test how well a person hears different sounds. The unit supports pure-tone and speech audiometry, along with selected special tests.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003eThis \u003cstrong\u003ediagnostic audiometer\u003c\/strong\u003e covers a listed frequency range of \u003cstrong\u003e125–8000 Hz\u003c\/strong\u003e. It has a 3.5-inch TFT screen and rotary controls. As a result, the operator can select test signals and review settings on the device.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eThe Elite 101 also supports standalone operation and PC-based work through USB. It is suited to ENT departments, audiology clinics and hearing test centres. However, tests must be carried out and reviewed by trained professionals using a correctly calibrated system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- KEY FEATURES --\u003e\n\u003cdiv style=\"padding: 23px; margin: 15px; background: #fff; border: 1px solid #e3edf3; border-radius: 15px;\"\u003e\n\u003ch2 style=\"color: #006093; font-size: 22px; margin: 0 0 13px; border-left: 5px solid #fc6c15; padding-left: 12px;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul style=\"padding-left: 21px; margin: 0;\"\u003e\n\u003cli style=\"margin-bottom: 9px;\"\u003e\n\u003cstrong\u003eTwo Test Channels:\u003c\/strong\u003e Supports clinical hearing tests with flexible sound and masking inputs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 9px;\"\u003e\n\u003cstrong\u003ePure-Tone Tests:\u003c\/strong\u003e Provides air conduction and bone conduction test support. Free-field testing needs suitable accessories.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 9px;\"\u003e\n\u003cstrong\u003eSpeech Testing:\u003c\/strong\u003e Supports live and recorded speech tests as listed in the model brochure.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 9px;\"\u003e\n\u003cstrong\u003eMasking Options:\u003c\/strong\u003e White noise, narrow-band noise and speech noise aid test setup when required.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 9px;\"\u003e\n\u003cstrong\u003eSpecial Tests:\u003c\/strong\u003e Includes SISI and Tone Decay functions for selected hearing assessments.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 9px;\"\u003e\n\u003cstrong\u003e3.5-Inch Screen:\u003c\/strong\u003e Helps the operator see test details and manage the interface.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 9px;\"\u003e\n\u003cstrong\u003eUSB PC Link:\u003c\/strong\u003e Supports standalone use or PC-based work with the compatible Acoustic Suite software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePatient Record Storage:\u003c\/strong\u003e The brochure lists internal memory for up to 2,000 patients.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- CLINICAL SECTION --\u003e\n\u003cdiv style=\"padding: 23px; margin: 15px; background: #fff; border: 1px solid #e3edf3; border-radius: 15px;\"\u003e\n\u003ch2 style=\"color: #006093; font-size: 22px; margin: 0 0 12px; border-left: 5px solid #fc6c15; padding-left: 12px;\"\u003eFor Audiologists and ENT Specialists\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003eFirst, the clinician chooses a test and checks the calibrated transducer. During pure-tone audiometry, the patient signals when a sound is heard. The clinician then records hearing thresholds across the required frequencies.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003eAir and bone conduction results can help the specialist assess hearing patterns. Also, masking may be used when one ear could affect the result for the other. Speech tests and special tests provide more data when clinically needed.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eThe unit can work on its own or connect to a PC. However, it does not replace clinical judgement, otoscopy or other tests when indicated. For reliable results, use a suitable test room and follow the device calibration schedule.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n\u003cdiv style=\"padding: 23px; margin: 15px; background: #fff; border: 1px solid #e3edf3; border-radius: 15px;\"\u003e\n\u003ch2 style=\"color: #006093; font-size: 22px; margin: 0 0 13px; border-left: 5px solid #fc6c15; padding-left: 12px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #006093; color: #fff;\"\u003e\n\u003cth scope=\"col\" style=\"padding: 11px; border: 1px solid #d8e5ec; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding: 11px; border: 1px solid #d8e5ec; text-align: left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec; background: #f3f9fc;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec;\"\u003eElite 101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec; background: #f3f9fc;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec;\"\u003eDiagnostic Audiometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec; background: #f3f9fc;\"\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec; background: #f3f9fc;\"\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec;\"\u003e125–8000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec; background: #f3f9fc;\"\u003e\u003cstrong\u003eAir Conduction Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec;\"\u003e−10 to 120 dB HL (transducer-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec; background: #f3f9fc;\"\u003e\u003cstrong\u003eBone Conduction Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec;\"\u003e−10 to 80 dB HL (frequency-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec; background: #f3f9fc;\"\u003e\u003cstrong\u003eTest Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec;\"\u003ePure Tone (AC\/BC), Speech, SISI, Tone Decay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec; background: #f3f9fc;\"\u003e\u003cstrong\u003eMasking Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec;\"\u003eWhite, Narrow-Band and Speech Noise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec; background: #f3f9fc;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec;\"\u003e3.5-inch TFT, 320 × 480 Pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec; background: #f3f9fc;\"\u003e\u003cstrong\u003ePC Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec;\"\u003eBidirectional USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec; background: #f3f9fc;\"\u003e\u003cstrong\u003eOperating Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec;\"\u003eStandalone \/ PC-Based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec; background: #f3f9fc;\"\u003e\u003cstrong\u003eInternal Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec;\"\u003eUp to 2,000 Patient Records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec; background: #f3f9fc;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec;\"\u003e320 × 230 × 75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec; background: #f3f9fc;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #d8e5ec;\"\u003eApprox. 900 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 12px; color: #66727a; margin: 11px 0 0;\"\u003eTechnical values are from the Elite 101 product brochure. Maximum output levels depend on the selected frequency and transducer. Confirm the exact supplied configuration before purchase.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- TEST TYPES --\u003e\n\u003cdiv style=\"padding: 23px; margin: 15px; background: #fff; border: 1px solid #e3edf3; border-radius: 15px;\"\u003e\n\u003ch2 style=\"color: #006093; font-size: 22px; margin: 0 0 12px; border-left: 5px solid #fc6c15; padding-left: 12px;\"\u003eAvailable Hearing Test Functions\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(185px,1fr)); gap: 10px;\"\u003e\n\u003cdiv style=\"background: #f5faff; border: 1px solid #e3edf3; border-radius: 10px; padding: 14px;\"\u003e\n\u003cstrong style=\"color: #006093;\"\u003ePure Tone Audiometry\u003c\/strong\u003e\n\u003cp style=\"margin: 5px 0 0; font-size: 14px;\"\u003eTests hearing thresholds using air and bone conduction.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f5faff; border: 1px solid #e3edf3; border-radius: 10px; padding: 14px;\"\u003e\n\u003cstrong style=\"color: #006093;\"\u003eSpeech Audiometry\u003c\/strong\u003e\n\u003cp style=\"margin: 5px 0 0; font-size: 14px;\"\u003eSupports live and recorded speech test methods.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f5faff; border: 1px solid #e3edf3; border-radius: 10px; padding: 14px;\"\u003e\n\u003cstrong style=\"color: #006093;\"\u003eMasking\u003c\/strong\u003e\n\u003cp style=\"margin: 5px 0 0; font-size: 14px;\"\u003eProvides noise options for selected test conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f5faff; border: 1px solid #e3edf3; border-radius: 10px; padding: 14px;\"\u003e\n\u003cstrong style=\"color: #006093;\"\u003eSpecial Tests\u003c\/strong\u003e\n\u003cp style=\"margin: 5px 0 0; font-size: 14px;\"\u003eIncludes SISI and Tone Decay functions when required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- BUYING GUIDE --\u003e\n\u003cdiv style=\"padding: 23px; margin: 15px; background: #eaf7fd; border: 1px solid #bfddeb; border-radius: 15px;\"\u003e\n\u003ch2 style=\"color: #006093; font-size: 22px; margin: 0 0 12px;\"\u003eWhat Should Clinics Check Before Buying?\u003c\/h2\u003e\n\u003col style=\"padding-left: 21px; margin: 0;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRequired Tests:\u003c\/strong\u003e Confirm whether air, bone, speech and special tests meet your clinic's needs.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAccessories:\u003c\/strong\u003e Verify the headphones, bone vibrator, patient response switch and power supply in the final quotation.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eOptional Equipment:\u003c\/strong\u003e Check free-field speakers, insert earphones and sound booth items separately.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePC Workflow:\u003c\/strong\u003e Confirm the Acoustic Suite licence, USB connection and software setup.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Ask for the calibration certificate and future service schedule.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcurement:\u003c\/strong\u003e Confirm warranty, user training, delivery and installation assistance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003c!-- BASIC USE --\u003e\n\u003cdiv style=\"padding: 23px; margin: 15px; background: #fff; border: 1px solid #e3edf3; border-radius: 15px;\"\u003e\n\u003ch2 style=\"color: #006093; font-size: 22px; margin: 0 0 12px; border-left: 5px solid #fc6c15; padding-left: 12px;\"\u003eBasic Test Workflow\u003c\/h2\u003e\n\u003col style=\"padding-left: 21px; margin: 0;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eFirst, prepare the quiet testing area and check device calibration and accessories.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eNext, explain the test and place the correct transducer on the patient.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eSelect the test mode and starting settings according to the clinic's protocol.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003ePresent the tones or speech signals and record patient responses.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eUse masking or special tests when the clinician finds them necessary.\u003c\/li\u003e\n\u003cli\u003eFinally, review and document the results. Clean patient-contact parts as instructed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003c!-- CTA --\u003e\n\u003cdiv style=\"padding: 23px; margin: 15px; background: #eaf7fd; border: 1px solid #bfddeb; border-radius: 15px;\"\u003e\n\u003ch2 style=\"color: #006093; font-size: 22px; margin: 0 0 10px;\"\u003eSetting Up an ENT or Audiology Clinic?\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 13px;\"\u003eContact Medansh for Elite 101 audiometer details, availability and clinic purchase support. Share your required test functions, accessories and delivery location. Our team can help with a product enquiry; qualified audiology professionals should select the clinical setup.\u003c\/p\u003e\n\u003ca href=\"tel:+918586012345\" style=\"display: block; background: #fc6c15; color: #ffffff; text-decoration: none; padding: 14px 18px; border-radius: 9px; text-align: center; font-size: 18px; font-weight: bold;\"\u003eCall Medansh: +91 8586012345\u003c\/a\u003e\n\u003cp style=\"text-align: center; color: #586a75; font-size: 13px; margin: 10px 0 0;\"\u003eMeddey Technologies Pvt. Ltd. | Medansh Customer Support\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- FAQS --\u003e\n\u003cdiv style=\"padding: 23px; margin: 15px; background: #fff; border: 1px solid #e3edf3; border-radius: 15px;\"\u003e\n\u003ch2 style=\"color: #006093; font-size: 22px; margin: 0 0 15px; border-left: 5px solid #fc6c15; padding-left: 12px;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"color: #075f91; font-size: 16px; margin: 0 0 5px;\"\u003eWhat is an audiometer machine used for?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003eIt helps trained professionals measure hearing thresholds through controlled sound tests. The results support an overall hearing assessment.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91; font-size: 16px; margin: 0 0 5px;\"\u003eWhat frequency range does Elite 101 support?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003eThe listed range is 125–8000 Hz. Test output limits vary with the frequency and transducer.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91; font-size: 16px; margin: 0 0 5px;\"\u003eDoes Elite 101 support bone conduction testing?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003eYes. The brochure lists air and bone conduction audiometry. A compatible bone vibrator is required.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91; font-size: 16px; margin: 0 0 5px;\"\u003eCan this audiometer run without a computer?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003eYes. It supports standalone operation. It can also connect to a PC through USB for supported workflows.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91; font-size: 16px; margin: 0 0 5px;\"\u003eIs this the same as a tympanometer?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003eNo. Elite 101 is a hearing-test audiometer. A tympanometer is used to assess middle-ear function through different tests.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91; font-size: 16px; margin: 0 0 5px;\"\u003eIs a free-field speaker included?\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 12px;\"\u003eFree-field speakers are listed as optional in the product brochure. Confirm the accessory package before ordering.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91; font-size: 16px; margin: 0 0 5px;\"\u003eWho should operate this diagnostic audiometer?\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eA trained audiologist, ENT specialist or qualified clinical hearing-test professional should operate the equipment and review results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- SAFETY --\u003e\n\u003cdiv style=\"padding: 19px 22px; margin: 15px; background: #fff7ef; border: 1px solid #f8d9bd; border-left: 5px solid #fc6c15; border-radius: 13px;\"\u003e\n\u003ch2 style=\"color: #006093; font-size: 19px; margin: 0 0 8px;\"\u003eImportant Clinical and Safety Information\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eUse the audiometer only with trained clinical staff. Follow the supplied manual and approved hearing-test protocol. Confirm calibration before clinical use and ensure the patient can understand the instructions. Use approved, clean transducers. This device does not replace a full ENT or audiology assessment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- INTERNAL LINKS --\u003e\n\u003cdiv style=\"padding: 19px 22px; margin: 15px; background: #fff; border: 1px solid #e3edf3; border-radius: 13px;\"\u003e\n\u003ch2 style=\"color: #006093; font-size: 20px; margin: 0 0 9px; border-left: 5px solid #fc6c15; padding-left: 12px;\"\u003eExplore More Hearing and Diagnostic Equipment\u003c\/h2\u003e\n\u003cp style=\"margin: 0;\"\u003eExplore the \u003ca href=\"https:\/\/medansh.in\/collections\/devices\" style=\"color: #006093; text-decoration: underline; font-weight: bold;\" target=\"_blank\" rel=\"noopener\"\u003emedical devices collection\u003c\/a\u003e or view the \u003ca href=\"https:\/\/medansh.in\/products\/audiometer-tympanometer-tymplite\" style=\"color: #006093; text-decoration: underline; font-weight: bold;\" target=\"_blank\" rel=\"noopener\"\u003eTymplite tympanometer\u003c\/a\u003e for a different middle-ear test workflow. Choose equipment based on the required tests.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MeddeyGo","offers":[{"title":"Default Title","offer_id":67696703373585,"sku":"MSH1006378","price":89199.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0749\/1482\/4465\/files\/hearing_test_equipment.webp?v=1791623519","url":"https:\/\/medansh.in\/products\/audiometer-machine-elite-101","provider":"Medansh","version":"1.0","type":"link"}