{"product_id":"anesthesia-workstation","title":"Advanced Anesthesia Workstation for OT \u0026 ICU Use","description":"\u003cstyle\u003e\n.medansh-anesthesia section {\n  transition:box-shadow .2s ease;\n}\n.medansh-anesthesia section:hover {\n  box-shadow:0 6px 22px rgba(7,95,145,.08);\n}\n.medansh-anesthesia a {\n  transition:background .2s ease,transform .2s ease;\n}\n.medansh-anesthesia a:hover {\n  background:#d96512!important;\n  transform:translateY(-2px);\n}\n@media(max-width:640px){\n  .medansh-anesthesia section {\n    padding:18px!important;\n  }\n  .medansh-anesthesia h1 {\n    font-size:24px!important;\n  }\n  .medansh-anesthesia h2 {\n    font-size:21px!important;\n  }\n  .medansh-anesthesia table {\n    font-size:13px;\n  }\n  .medansh-anesthesia td,\n  .medansh-anesthesia th {\n    padding:9px!important;\n    overflow-wrap:anywhere;\n  }\n}\n\u003c\/style\u003e\n\u003cdiv class=\"medansh-anesthesia\" style=\"max-width: 1100px; margin: auto; font-family: Arial,sans-serif; color: #24313a; line-height: 1.7;\"\u003e\n\u003c!-- PRODUCT INTRODUCTION --\u003e\n\u003csection style=\"background: linear-gradient(135deg,#eaf7ff,#fff3ea); padding: 28px; border-radius: 20px; outline: 1px solid #cfe7f2;\"\u003e\u003cspan style=\"display: inline-block; background: #f47b20; color: #fff; padding: 8px 15px; border-radius: 25px; font-weight: bold;\"\u003e Professional Anesthesia \u0026amp; Ventilation Solution \u003c\/span\u003e\n\u003ch1 style=\"color: #075f91; margin: 14px 0 10px; font-size: 30px; line-height: 1.25;\"\u003eAnesthesia Workstation with Ventilator and 7 Inch TFT Display\u003c\/h1\u003e\n\u003cp\u003eThe anesthesia workstation available at Medansh is designed for controlled delivery of anesthetic gases and assisted ventilation in equipped operation theatres. This configuration accommodates adult and pediatric applications under the direction of qualified anesthesia professionals.\u003c\/p\u003e\n\u003cp\u003eDesigned for clinical flexibility, the system provides VCV, PCV, SIMV, manual and standby ventilation modes. It also supports semi-open, semi-closed and closed breathing circuit systems. The integrated 7-inch colour TFT display presents ventilation settings and monitored values for convenient observation during procedures.\u003c\/p\u003e\n\u003cp\u003eThe workstation combines oxygen, nitrous oxide and air flow controls with oxygen flush, pressure monitoring, integrated circle absorber and vaporizer mounting support. Its epoxy-coated frame, two storage drawers and onboard battery backup make it a practical option for organized operation theatre workflows.\u003c\/p\u003e\n\u003cbr\u003e\u003c\/section\u003e\n\u003c!-- KEY FEATURES --\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #fff; outline: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eKey Features of Anesthesia Workstation\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: separate; border-spacing: 10px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f7fbfe; border: 1px solid #d5eaf5; border-radius: 14px; padding: 16px; width: 50%; vertical-align: top;\"\u003e\n\u003ch3 style=\"color: #f47b20; margin-top: 0;\"\u003eAdult and Pediatric Support\u003c\/h3\u003e\n\u003cp\u003eSuitable for adult and pediatric anesthesia applications in appropriately equipped surgical environments.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"background: #f7fbfe; border: 1px solid #d5eaf5; border-radius: 14px; padding: 16px; width: 50%; vertical-align: top;\"\u003e\n\u003ch3 style=\"color: #f47b20; margin-top: 0;\"\u003eMultiple Ventilation Modes\u003c\/h3\u003e\n\u003cp\u003eSupports VCV, PCV, SIMV, manual and standby modes for different clinical ventilation requirements.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f7fbfe; border: 1px solid #d5eaf5; border-radius: 14px; padding: 16px; vertical-align: top;\"\u003e\n\u003ch3 style=\"color: #f47b20; margin-top: 0;\"\u003e7 Inch Colour TFT Display\u003c\/h3\u003e\n\u003cp\u003eDisplays ventilation settings, monitoring parameters and related information on a colour screen.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"background: #f7fbfe; border: 1px solid #d5eaf5; border-radius: 14px; padding: 16px; vertical-align: top;\"\u003e\n\u003ch3 style=\"color: #f47b20; margin-top: 0;\"\u003eIntegrated Circle Absorber\u003c\/h3\u003e\n\u003cp\u003eThe integrated circle absorber system supports carbon dioxide absorption and breathing circuit management.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f7fbfe; border: 1px solid #d5eaf5; border-radius: 14px; padding: 16px; vertical-align: top;\"\u003e\n\u003ch3 style=\"color: #f47b20; margin-top: 0;\"\u003eGas Flow Management\u003c\/h3\u003e\n\u003cp\u003eOxygen, nitrous oxide and air flow meter support allows controlled gas flow adjustment during anesthesia delivery.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"background: #f7fbfe; border: 1px solid #d5eaf5; border-radius: 14px; padding: 16px; vertical-align: top;\"\u003e\n\u003ch3 style=\"color: #f47b20; margin-top: 0;\"\u003eStrong Workstation Frame\u003c\/h3\u003e\n\u003cp\u003eHigh-strength epoxy-coated frame with two storage drawers for equipment organization.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #fff; outline: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"background: #075f91; color: #fff; padding: 12px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background: #075f91; color: #fff; padding: 12px; text-align: left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003ePatient Application\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003ePediatric and Adult Patients\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eTidal Volume\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e20 ml – 1500 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eVentilation Modes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eVCV, PCV, SIMV, Manual, Standby\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eDriven Mode\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003ePneumatically Driven, Electronically Controlled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eCircuit Modes\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eSemi Open, Semi Closed, Closed System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e7 Inch Colour TFT Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eLung Mechanics\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eLung Mechanics and Loops, P-V and V-F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eGas Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eO2, N2O and Air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eFlow Meter Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eFive Tube Bobbin Type Flow Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eO2 Flow Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e0.1–1 L\/min and 1–10 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eN2O Flow Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e0.1–1 L\/min and 1–12 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eAir Flow Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e0.1–15 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eSafety Linkage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eO2 and N2O Linkage Device with Hypoxy Guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eOxygen Flush\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e25 L\/min – 75 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eGas Source Pressure\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eO2, N2O and Air: 0.25 MPa – 0.65 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eVaporizer Mount\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eSelect Tec Bar Support, 2 Interlocked Vaporizers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eVaporizer Compatibility\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eHalothane, Isoflurane, Sevoflurane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eCircle Absorber System\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eIntegrated Circle Absorber with Twin Large Volume CO2 Absorber, Non-Return Respiratory Valve, Expiratory Valve and APL Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eMeasured Pressure Values\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eP Peak, Pmean, Pplat, Pmin, PEEP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eMeasured Ventilation Values\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eMV, Vt, SPONT, Ftotal, fspn, I:E Ratio 4:1–1:8, Rinsp, Cdyn, FiO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eAlarm Parameters\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eMV, Pressure, Vte, Rate, FiO2, Battery Low, Battery Discharged, O2 Supply Failure, Apnea, Circuit Occlusion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eFrame\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eRust-Proof Epoxy-Coated High Strength Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e2 Big Drawers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003ePipeline Attachment\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eFor O2 and N2O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eYoke Support\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e2 Each for O2 and N2O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e220V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eBattery Backup\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e12V DC, Minimum 120 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e150 x 67 x 60 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eOptional Feature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eBasal Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size: 13px; color: #526877;\"\u003eSpecifications are based on the supplied product information. Confirm the exact model and final configuration before purchase.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c!-- PRODUCT BENEFITS --\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #fff; outline: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eProduct Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSupports controlled anesthesia delivery during surgical procedures.\u003c\/li\u003e\n\u003cli\u003eSuitable for adult and pediatric anesthesia applications.\u003c\/li\u003e\n\u003cli\u003eMultiple ventilation modes support different clinical requirements.\u003c\/li\u003e\n\u003cli\u003e7-inch colour TFT display makes monitored settings and values easier to read.\u003c\/li\u003e\n\u003cli\u003eO2, N2O and air flow meter support assists gas delivery management.\u003c\/li\u003e\n\u003cli\u003eIntegrated circle absorber supports breathing circuit management.\u003c\/li\u003e\n\u003cli\u003eAlarm functionality helps notify staff of monitored conditions requiring attention.\u003c\/li\u003e\n\u003cli\u003eHigh-strength frame and storage drawers support organized OT workflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c!-- APPLICATIONS --\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #fff; outline: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eApplications and Use Cases\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; background: #f7fbfe; padding: 14px; width: 50%; vertical-align: top;\"\u003e\n\u003cstrong\u003eOperation Theatres\u003c\/strong\u003e\n\u003cp\u003eDesigned for controlled anesthesia delivery and respiratory support during surgical procedures.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; background: #f7fbfe; padding: 14px; width: 50%; vertical-align: top;\"\u003e\n\u003cstrong\u003eCritical Care Environments\u003c\/strong\u003e\n\u003cp\u003ePotential use in settings where the model specifications and institutional clinical protocols permit.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; background: #f7fbfe; padding: 14px; vertical-align: top;\"\u003e\n\u003cstrong\u003eTrauma Centres\u003c\/strong\u003e\n\u003cp\u003eSupports anesthesia management during emergency surgical procedures.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; background: #f7fbfe; padding: 14px; vertical-align: top;\"\u003e\n\u003cstrong\u003eMultispecialty Hospitals\u003c\/strong\u003e\n\u003cp\u003eSuitable for appropriately equipped hospital surgical departments managing adult and pediatric procedures.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003c!-- WHO SHOULD BUY --\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #fff7f0; outline: 1px solid #f7d6bd; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eWho Should Buy This Product?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMultispecialty hospitals\u003c\/li\u003e\n\u003cli\u003eOperation theatres and surgical departments\u003c\/li\u003e\n\u003cli\u003eAnesthesiology departments\u003c\/li\u003e\n\u003cli\u003eTrauma and emergency surgical centres\u003c\/li\u003e\n\u003cli\u003eHealthcare facilities equipped for adult and pediatric anesthesia care\u003c\/li\u003e\n\u003cli\u003eHospital procurement teams comparing anesthesia workstations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c!-- SAFETY GUIDANCE --\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #fff; outline: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eUsage and Safety Guidance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUse only under the supervision of a trained anesthesiologist or appropriately qualified clinical professional.\u003c\/li\u003e\n\u003cli\u003eInspect gas connections, pipeline attachments, yoke connections and electrical supply before use.\u003c\/li\u003e\n\u003cli\u003eVerify the selected ventilation mode, circuit configuration and alarm settings before every procedure.\u003c\/li\u003e\n\u003cli\u003eCheck vaporizer compatibility and gas supply pressure according to the manufacturer's instructions.\u003c\/li\u003e\n\u003cli\u003eContinuously monitor the patient's condition during anesthesia administration.\u003c\/li\u003e\n\u003cli\u003eMaintain emergency airway management and resuscitation equipment according to institutional OT protocols.\u003c\/li\u003e\n\u003cli\u003eClean and maintain the workstation according to applicable infection-control procedures.\u003c\/li\u003e\n\u003cli\u003eFollow the manufacturer's recommended inspection, calibration, preventive maintenance and servicing schedules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c!-- WHY CHOOSE MEDANSH --\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #fff; outline: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eWhy Consider This Anesthesia Workstation at Medansh?\u003c\/h2\u003e\n\u003cp\u003eThis anesthesia workstation brings gas flow management, multiple ventilation modes, oxygen flush functionality, a circle absorber and monitored ventilation parameters together in one integrated configuration.\u003c\/p\u003e\n\u003cp\u003eThe compact workstation layout and two storage drawers provide practical space for organizing compatible accessories around the anesthesia station. Its colour TFT display helps clinical teams access relevant settings and monitoring information.\u003c\/p\u003e\n\u003cp\u003eAt Medansh.in, healthcare buyers can explore the equipment specifications and assess their suitability for operation theatres, surgical departments and hospital infrastructure requirements.\u003c\/p\u003e\n\u003cp\u003eBefore purchasing, confirm the final supplied configuration, installation requirements, compatible accessories, maintenance needs and available service arrangements.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c!-- BUYING GUIDANCE --\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #fff; outline: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eBuying Guidance\u003c\/h2\u003e\n\u003cp\u003eWhen selecting an anesthesia workstation for a hospital or surgical facility, consider the clinical application, patient categories, ventilation requirements and compatibility with the existing operation theatre infrastructure.\u003c\/p\u003e\n\u003cp\u003eReview the available ventilation modes, tidal volume range, gas flow requirements, vaporizer mounting system, oxygen flush, circle absorber configuration and monitoring parameters.\u003c\/p\u003e\n\u003cp\u003eAlso check the workstation dimensions, power requirements, battery backup, pipeline connections, training requirements and maintenance provisions before finalizing the purchase.\u003c\/p\u003e\n\u003cp\u003eConfirm whether compatible vaporizers, breathing circuit accessories and other required components are included in the selected product configuration or need to be purchased separately.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c!-- CALL TO ACTION --\u003e\n\u003csection style=\"margin-top: 22px; padding: 26px; background: #075f91; color: #fff; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #fff; margin-top: 0;\"\u003eExplore Anesthesia Workstation at Medansh\u003c\/h2\u003e\n\u003cp\u003ePlanning an operation theatre equipment purchase? Explore this anesthesia workstation with multiple ventilation modes, 7-inch colour TFT display and integrated gas flow management features.\u003c\/p\u003e\n\u003cp\u003eReview the technical specifications and choose a configuration aligned with your hospital's clinical and infrastructure requirements.\u003c\/p\u003e\n\u003cbr\u003e\u003c\/section\u003e\n\u003c!-- FAQ SECTION --\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #fff; outline: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"color: #075f91;\"\u003e1. What is an anesthesia workstation used for?\u003c\/h3\u003e\n\u003cp\u003eAn anesthesia workstation is used to deliver anesthetic gases and provide respiratory support during surgical procedures under qualified clinical supervision.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91;\"\u003e2. Can this anesthesia machine be used for adult and pediatric patients?\u003c\/h3\u003e\n\u003cp\u003eYes. The supplied specifications identify support for adult and pediatric patient applications.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91;\"\u003e3. What ventilation modes are available?\u003c\/h3\u003e\n\u003cp\u003eThe workstation supports VCV, PCV, SIMV, manual and standby ventilation modes.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91;\"\u003e4. What is the tidal volume range?\u003c\/h3\u003e\n\u003cp\u003eThe specified tidal volume range is 20 ml to 1500 ml.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91;\"\u003e5. Does this anesthesia workstation have a colour display?\u003c\/h3\u003e\n\u003cp\u003eYes. It includes a 7-inch colour TFT display for reviewing ventilation settings and monitored parameters.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91;\"\u003e6. What gases does the workstation support?\u003c\/h3\u003e\n\u003cp\u003eThe workstation supports oxygen (O2), nitrous oxide (N2O) and air supply connections.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91;\"\u003e7. Does the anesthesia workstation include battery backup?\u003c\/h3\u003e\n\u003cp\u003eAccording to the supplied specifications, it features 12V DC battery backup rated for a minimum of 120 minutes.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91;\"\u003e8. What are the workstation dimensions?\u003c\/h3\u003e\n\u003cp\u003eThe specified dimensions are 150 x 67 x 60 cm.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91;\"\u003e9. Who should operate this anesthesia workstation?\u003c\/h3\u003e\n\u003cp\u003eIt should be operated only by trained anesthesiologists or appropriately qualified healthcare professionals following the manufacturer's instructions and institutional safety protocols.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Medansh","offers":[{"title":"Default Title","offer_id":67843413934353,"sku":"MSH1000881","price":349999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0749\/1482\/4465\/files\/anesthesia_machine_use.webp?v=1792664252","url":"https:\/\/medansh.in\/products\/anesthesia-workstation","provider":"Medansh","version":"1.0","type":"link"}