{"product_id":"3-channel-ecg-machine-7-inch-touch-12-lead-support","title":"3 Channel ECG Machine 7 Inch Touch 12 Lead Support","description":"\u003cdiv style=\"max-width: 1100px; margin: auto; font-family: Arial, sans-serif; color: #24313a; line-height: 1.7; font-size: 15px;\"\u003e\n\u003csection style=\"background: linear-gradient(135deg,#eaf7ff,#fff3ea); padding: 28px; border-radius: 20px; border: 1px solid #cfe7f2;\"\u003e\u003cbr\u003e\n\u003ch1 style=\"color: #075f91; margin: 14px 0 10px; font-size: 30px; line-height: 1.25;\"\u003e3 Channel ECG Machine with 7 Inch Touch Display \u0026amp; 12 Lead Support\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003e3 Channel ECG Machine with 12 Lead Support\u003c\/strong\u003e from \u003cstrong\u003eMedansh\u003c\/strong\u003e is designed for hospitals, clinics, diagnostic centres, OPD rooms and emergency care areas where reliable ECG testing and cardiac assessment support are required.\u003c\/p\u003e\n\u003cp\u003eThis electrocardiogram machine supports \u003cstrong\u003estandard 12 lead ECG acquisition\u003c\/strong\u003e, helping healthcare professionals record cardiac electrical activity during routine screening, patient evaluation and clinical monitoring. It is suitable for ECG testing workflows where clear recording, flexible report settings and thermal printing are important.\u003c\/p\u003e\n\u003cp\u003eWith simultaneous 12 lead acquisition, multiple recording modes, selectable rhythm lead, thermal printing and built-in battery support, this ECG machine is useful for OPD testing, bedside ECG recording, health check-ups, diagnostic centres and emergency cardiac evaluation.\u003c\/p\u003e\n\u003c!-- Replace this with Medansh product image URL --\u003e\u003c\/section\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #ffffff; border: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eKey Features\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: separate; border-spacing: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f7fbfe; border: 1px solid #d5eaf5; border-radius: 14px; padding: 16px; width: 50%; vertical-align: top;\"\u003e\n\u003ch3 style=\"color: #f47b20; margin-top: 0;\"\u003eStandard 12 Lead ECG\u003c\/h3\u003e\n\u003cp\u003eSupports standard 12 lead ECG recording for complete cardiac signal assessment.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"background: #f7fbfe; border: 1px solid #d5eaf5; border-radius: 14px; padding: 16px; width: 50%; vertical-align: top;\"\u003e\n\u003ch3 style=\"color: #f47b20; margin-top: 0;\"\u003eSimultaneous 12 Lead Acquisition\u003c\/h3\u003e\n\u003cp\u003eCaptures 12 lead data together to support faster and more consistent ECG workflow.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f7fbfe; border: 1px solid #d5eaf5; border-radius: 14px; padding: 16px; vertical-align: top;\"\u003e\n\u003ch3 style=\"color: #f47b20; margin-top: 0;\"\u003eThermal Printing System\u003c\/h3\u003e\n\u003cp\u003ePrints ECG reports on 80 mm roll paper for quick clinical documentation and patient records.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"background: #f7fbfe; border: 1px solid #d5eaf5; border-radius: 14px; padding: 16px; vertical-align: top;\"\u003e\n\u003ch3 style=\"color: #f47b20; margin-top: 0;\"\u003eMultiple Paper Speeds\u003c\/h3\u003e\n\u003cp\u003eSupports 12.5 mm\/s, 25 mm\/s and 50 mm\/s paper speeds for flexible ECG reporting.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background: #f7fbfe; border: 1px solid #d5eaf5; border-radius: 14px; padding: 16px; vertical-align: top;\"\u003e\n\u003ch3 style=\"color: #f47b20; margin-top: 0;\"\u003eBuilt-in Battery Support\u003c\/h3\u003e\n\u003cp\u003eRechargeable lithium battery support helps maintain operation during movement, bedside use or power changes.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"background: #f7fbfe; border: 1px solid #d5eaf5; border-radius: 14px; padding: 16px; vertical-align: top;\"\u003e\n\u003ch3 style=\"color: #f47b20; margin-top: 0;\"\u003eClinical Safety Support\u003c\/h3\u003e\n\u003cp\u003eIncludes protection against defibrillator effect and low patient leak current support for safer clinical operation.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #ffffff; border: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"background: #075f91; color: #ffffff; padding: 12px; text-align: left; border: 1px solid #075f91;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"background: #075f91; color: #ffffff; padding: 12px; text-align: left; border: 1px solid #075f91;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eLead\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eStandard 12 Leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eAcquisition Mode\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eSimultaneous 12 Leads Acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e±5mVpp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eInput Circuit\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eFloating; protection circuit against defibrillator effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e≥50MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eInput Circuit Current\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e\u0026lt;0.05μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eCMRR\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e\u0026gt;100dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003ePatient Leak Current\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e\u0026lt;10μA at 220V–240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eFrequency Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e0.05Hz–150Hz (-3dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eSensitivity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e2.5mm\/mV, 5mm\/mV, 10mm\/mV, 20mm\/mV; error ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eAnti-Baseline Drift\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eTime Constant\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e≥3.2s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eNoise Level\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e\u0026lt;15μV p-p\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003ePaper Speed\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e12.5mm\/s, 25mm\/s, 50mm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eRecording Mode\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eThermal Printing System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003ePaper Specification\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eRoll 80mm x 20m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eAutomatic Record Mode\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e3CHx4+1R, 3CHx4, 3CHx2+2CHx3, 3CHx2+2CHx3+1R, 6CHx2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eManual Mode\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e3CH, 2CH, 3CH+1R, 2CH+1R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eRhythm\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eAny lead selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eFilter\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eEMG: 25Hz \/ 30Hz \/ 40Hz \/ 75Hz \/ 100Hz \/ 150Hz; DFT: 0.05Hz \/ 0.15Hz; AC: 50Hz \/ 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eSafety Standard\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eIEC I \/ CF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eSample Rate\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eNormal: 1000sps\/channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eAC: 100–240V, 50\/60Hz, 30VA–100VA; DC: 14.8V\/2200mAh built-in lithium battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003eSingle Gross Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; padding: 12px;\"\u003e2.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #ffffff; border: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eProduct Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSupports ECG recording for routine cardiac assessment and clinical evaluation.\u003c\/li\u003e\n\u003cli\u003eStandard 12 lead ECG acquisition helps provide a complete cardiac signal view.\u003c\/li\u003e\n\u003cli\u003eThermal printing supports quick ECG report generation for clinical records.\u003c\/li\u003e\n\u003cli\u003eBuilt-in battery support helps during bedside testing, movement or power changes.\u003c\/li\u003e\n\u003cli\u003eMultiple paper speeds and sensitivity settings support flexible ECG testing needs.\u003c\/li\u003e\n\u003cli\u003eSelectable rhythm lead helps clinical teams record ECG data as per requirement.\u003c\/li\u003e\n\u003cli\u003eSuitable for hospitals, clinics, diagnostic centres, OPDs and emergency units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #ffffff; border: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eCommon Uses\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; background: #f7fbfe; padding: 14px;\"\u003e\n\u003cstrong\u003eHospital ECG Testing\u003c\/strong\u003e\u003cbr\u003eUseful for cardiac assessment in wards, OPDs, emergency care areas and cardiology departments.\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; background: #f7fbfe; padding: 14px;\"\u003e\n\u003cstrong\u003eClinic Screening\u003c\/strong\u003e\u003cbr\u003eSuitable for routine heart rhythm screening in clinics, consultation rooms and health check-up areas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; background: #f7fbfe; padding: 14px;\"\u003e\n\u003cstrong\u003eDiagnostic Centres\u003c\/strong\u003e\u003cbr\u003eSupports ECG report printing and structured patient testing workflows for diagnostic facilities.\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d5eaf5; background: #f7fbfe; padding: 14px;\"\u003e\n\u003cstrong\u003e12 Lead ECG Recording\u003c\/strong\u003e\u003cbr\u003eHelps trained staff perform standard ECG recording with proper leads and placement protocol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #fff7f0; border: 1px solid #f7d6bd; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eWho Should Buy This Product?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHospitals and emergency departments\u003c\/li\u003e\n\u003cli\u003eClinics and OPD consultation rooms\u003c\/li\u003e\n\u003cli\u003eDiagnostic centres and cardiac screening setups\u003c\/li\u003e\n\u003cli\u003eDoctors, cardiology units and healthcare professionals\u003c\/li\u003e\n\u003cli\u003eMedical buyers looking for a standard 12 lead ECG machine\u003c\/li\u003e\n\u003cli\u003eHealthcare facilities needing a reliable electrocardiogram machine for routine use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #ffffff; border: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eWhy Choose This Electrocardiogram Machine from Medansh?\u003c\/h2\u003e\n\u003cp\u003eThis \u003cstrong\u003e3 Channel ECG Machine with 12 Lead Support\u003c\/strong\u003e is a practical choice for healthcare spaces that need standard ECG acquisition, report printing and flexible recording settings. It supports clinical ECG workflows while keeping operation convenient for trained users.\u003c\/p\u003e\n\u003cp\u003eWith simultaneous 12 lead acquisition, thermal printing, selectable rhythm lead, multiple sensitivity settings and built-in battery support, this ECG machine is suitable for clinics, hospitals, diagnostic centres and emergency care setups. With \u003cstrong\u003eMedansh\u003c\/strong\u003e, healthcare buyers can source dependable diagnostic and medical equipment for professional use.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #ffffff; border: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eQuick Tips for Use\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePlace ECG electrodes correctly as per standard ECG leads and placement protocol.\u003c\/li\u003e\n\u003cli\u003eKeep the patient relaxed and still during recording for cleaner waveforms.\u003c\/li\u003e\n\u003cli\u003eSelect paper speed and sensitivity according to clinical reporting need.\u003c\/li\u003e\n\u003cli\u003eUse filters carefully to reduce interference without affecting interpretation.\u003c\/li\u003e\n\u003cli\u003eCheck paper roll, battery charge and lead cables before ECG testing.\u003c\/li\u003e\n\u003cli\u003eECG interpretation should always be done by qualified healthcare professionals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #ffffff; border: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eBuying Guidance\u003c\/h2\u003e\n\u003cp\u003eChoose this electrocardiogram machine if your clinic, hospital or diagnostic centre needs standard 12 lead ECG support, thermal printing, selectable rhythm lead, multiple paper speeds and battery backup.\u003c\/p\u003e\n\u003cp\u003eBefore purchasing, check your ECG testing workflow, patient volume, reporting requirement, paper roll availability, staff training and service support. This machine should be operated by trained healthcare staff, and ECG results should be reviewed by qualified medical professionals.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-top: 22px; padding: 26px; background: #075f91; color: #ffffff; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #ffffff; margin-top: 0;\"\u003eBuy Electrocardiogram Machine Online from Medansh\u003c\/h2\u003e\n\u003cp\u003eUpgrade your diagnostic setup with an ECG machine designed for standard 12 lead ECG testing, report printing and professional clinical use. Explore more diagnostic and medical equipment for hospitals, clinics and diagnostic centres at Medansh.\u003c\/p\u003e\n\u003cbr\u003e\u003c\/section\u003e\n\u003csection style=\"margin-top: 22px; padding: 24px; background: #ffffff; border: 1px solid #dcecf4; border-radius: 18px;\"\u003e\n\u003ch2 style=\"color: #075f91; margin-top: 0;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"color: #075f91;\"\u003eWhat is an electrocardiogram machine used for?\u003c\/h3\u003e\n\u003cp\u003eAn electrocardiogram machine is used to record the electrical activity of the heart for clinical assessment and cardiac evaluation.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91;\"\u003eDoes this ECG machine support 12 lead ECG?\u003c\/h3\u003e\n\u003cp\u003eYes, this ECG machine supports standard 12 lead ECG acquisition for complete cardiac signal recording.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91;\"\u003eWhat is the use of ECG leads and placement?\u003c\/h3\u003e\n\u003cp\u003eProper ECG leads and placement help capture heart signals from different body positions for accurate ECG recording.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91;\"\u003eCan this ECG machine print reports?\u003c\/h3\u003e\n\u003cp\u003eYes, it supports thermal printing with 80mm x 20m roll paper.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91;\"\u003eIs this ECG machine suitable for clinics?\u003c\/h3\u003e\n\u003cp\u003eYes, it is suitable for clinics, hospitals, diagnostic centres, OPDs and emergency care units.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91;\"\u003eDoes this machine have battery backup?\u003c\/h3\u003e\n\u003cp\u003eYes, it supports DC 14.8V\/2200mAh built-in lithium battery operation.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91;\"\u003eWho should operate this ECG machine?\u003c\/h3\u003e\n\u003cp\u003eThis ECG machine should be operated by trained healthcare staff, ECG technicians or qualified medical professionals.\u003c\/p\u003e\n\u003ch3 style=\"color: #075f91;\"\u003eCan ECG results be self-interpreted?\u003c\/h3\u003e\n\u003cp\u003eNo, ECG findings should be interpreted by qualified doctors or cardiology professionals.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Medansh","offers":[{"title":"Default Title","offer_id":53724391637265,"sku":"MSH1004445","price":19779.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0749\/1482\/4465\/files\/ecg_mahine_use.webp?v=1782890756","url":"https:\/\/medansh.in\/products\/3-channel-ecg-machine-7-inch-touch-12-lead-support","provider":"Medansh","version":"1.0","type":"link"}